EUCHNER Evaluation unit CES-A-AEA-02B/CES-A-UEA-02B (for 2 read heads) ; 092560
Evaluation unit CES-A-AEA-02B/CES-A-UEA-02B (for 2 read heads) ; 092560 2 read heads can be connected 2 safety contacts (relay contacts) 1 internal normally open...
Cena na upit
Evaluation unit CES-A-AEA-02B/CES-A-UEA-02B (for 2 read heads) ; 092560
- 2 read heads can be connected
- 2 safety contacts (relay contacts)
- 1 internal normally open contact per safety contact
- Start button and feedback loop can be connected
- Unicode evaluation unit
- Category 4 / PL e according to EN ISO 13849-1
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | max. 10 % |
Operating and display elements
LED display | |
Diagnostics LED | |
Status LED | |
Safety outputs status |
Item | Extras | Color | Designation1 | Number | LED | Note slide-in label | Switching element | Slide-in label | Version |
---|---|---|---|---|---|---|---|---|---|
Configuration setting for teach-in operation | DIP switches (H1, H2, S, Y) |
Electrical connection values
Fuse | |
external (operating voltage UB) | 0.25 ... 8 A |
Connection cross section | |
(screw terminals) | 0.25 ... 2.5 mm² |
Operating voltage DC | |
UB | 21 ... 24 ... 27 V DC regulated, residual ripple<5% |
EMC protection requirements | Acc. to EN 60947-5-3 |
Current consumption | |
(with relay energized) | 150 mA |
Current via feedback loop | 5 ... 8 ... 10 mA |
Degree of contamination (external, according to EN 60947-1) | 2 |
permissible resistance in feedback loop | max. 600 Ω |
Inputs: start button S, test input TST | |
Input voltage | |
LOW | 0 ... 2 V DC |
HIGH | 15 ... UB V DC |
Input current | |
HIGH | 5 ... 8 ... 10 mA |
Monitoring outputs: diagnostics DIA, door monitoring outputs O1,O2 | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output voltage | 0.8 x UB ... UB V DC |
Switching current | max. 20 mA |
Safety contacts 13/14, 23/24 | |
Fuse | |
external (safety circuit) according to EN 60269-1 | 6 AgG or 6 A circuit breaker (characteristic B or C) |
Output type | Relay contacts, floating |
rated conditional short-circuit current | 100 A |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 4 kV |
Discrepancy time | |
(between the operating points of both relays, with 2 active actuators) | max. 240 ms |
Utilization category | |
DC-13 | 24 V 1.2 A |
DC-12 | 60 V 0.3 A |
AC-12 | 30 V 6 A |
AC-12 | 60 V 0.3 A |
AC-15 | 230 V 1.5 A |
DC-12 | 30 V 6 A |
Switching load | |
according to c UL us | Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A |
Switching current | |
at switching voltage AC 17 ... 230 V | 15 ... 1500 mA |
at switching voltage AC/DC 1 ... 60 V | 1 ... 300 mA |
at switching voltage AC/DC 17 ... 30 V | 15 ... 6000 mA |
Mechanical values and environment
Connection type | Screw terminals |
Number of read heads | Max. 2 read heads can be connected. |
Ready delay | 10 ... 12 s |
Switching frequency | max. 0.25 Hz |
Atmospheric humidity | |
not condensing | max. 80 % rH |
Mounting distance | |
laterally to the neighboring device | min. 10 mm |
Mounting type | Mounting rail 35 mm according to DIN EN 60715 TH35 |
Response time | |
after change in the actuation status, 1 active actuator | max. 210 ms |
Start button response delay (for Manual start operating mode) | 200 ... 300 ms |
after change in the actuation status, 2 active actuators | max. 290 ms |
Start button actuating duration (for Manual Start operating mode) | min. 250 ms |
Degree of protection | IP20 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Dwell time | min. 3 s |
Material | |
Housing | Plastic PA6.6 |
Safety contacts 13/14, 23/24 | |
Number of safety contacts | 2 Relay with internally monitored contacts |
Mechanical life | |
Operating cycles (relay) | 10 x 10⁶ |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Number of switching cycles | |
≤ 1 A at 24 V DC | max. 100000 1/y |
≤ 3 A at 24 V DC | max. 23000 1/y |
≤ 0.1 A at 24 V DC | max. 506000 1/y |
Diagnostic Coverage (DC) | 99 % |
Mission time | 20 y |
Monitoring of the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 1.3 x 10-8 |
Miscellaneous
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures. |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V
Mounting distance | |
neighboring read heads | min. 50 mm |
In combination with read head CES-A-LQA-SC and actuator CES-A-BQA
Switch-on distance | |
for vertical approach direction (center offset m=0) | 23 mm |
for side approach direction (distance in x direction 10 mm) | +/- 28 mm |
Secured switch-off distance sar | max. 60 mm |
Secured switching distance sao | |
for side approach direction (distance in x direction 10 mm) | min. +/- 24 mm |
for vertical approach direction (center offset m=0) | min. 16 mm |
Switching hysteresis | |
for vertical approach direction (center offset m=0) | 2 ... 3 mm |
for side approach direction (distance in x direction 10 mm) | 1 ... 1.3 mm |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA
Actuator distance s | |
Minimum distance for side approach direction | min. 3 mm |
Switch-on distance | |
with center offset m=0 | 15 mm |
Secured switch-off distance sar | max. 32 mm |
Secured switching distance sao | |
with center offset m=0 | min. 10 mm |
Switching hysteresis | 0.5 ... 2 mm |
In combination with read head CES-A-LQA-SC
Mounting distance | |
neighboring read heads | min. 80 mm |
In combination with read head CES-A-LMN-SC
Mounting distance | |
neighboring read heads | min. 20 mm |
In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA
Switch-on distance | |
for side approach direction (distance in x direction 8 mm) | +/- 22 mm |
for vertical approach direction (center offset m=0) | 15 mm |
Secured switch-off distance sar | max. 47 mm |
Secured switching distance sao | |
for side approach direction (distance in x direction 8 mm) | min. +/- 18 mm |
for vertical approach direction (center offset m=0) | min. 10 mm |
Switching hysteresis | |
for side approach direction (distance in x direction 8 mm) | 1 ... 1.8 mm |
for vertical approach direction (center offset m=0) | 2 ... 3 mm |
In combination with read head CES-A-LMN-SC and actuator CES-A-BMB
Actuator distance s | |
Minimum distance | min. 1.2 mm |
Switch-on distance | |
with center offset m=0 | 5 mm |
Secured switch-off distance sar | max. 10 mm |
Secured switching distance sao | |
with center offset m=0 | min. 3.5 mm |
Switching hysteresis | 0.1 ... 0.3 mm |
In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20
Actuator distance s | |
Minimum distance for side approach direction | min. 4 mm |
Switch-on distance | |
with center offset m=0 | 16 mm |
Secured switch-off distance sar | max. 33 mm |
Secured switching distance sao | |
with center offset m=0 | min. 11 mm |
Switching hysteresis | 0.5 ... 2 mm |
Slicni proizvodi:
EUCHNER Non-contact safety switches CES-I-AR-U-C04-U20-119472; 119472
Non-contact safety switches CES-I-AR-.-C04-…, flying lead Safety switch with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Non-contact safety switches CES-I-AP-U-C14-U20-158632; 158632
Non-contact safety switches CES-I-AP-.-C14-…, with cable end sleeves Safety switch with integrated evaluation electronics Safety switch CES-C04 encapsulated
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Non-contact safety switches CES-I-AP-M-C04-USI-160832; 160832
Non-contact safety switches CES-I-AP-.-C04-, M12; pin 5 not used Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
(Trenutno nema na stanju)
Cena na upit