EUCHNER Evaluation unit CES-AZ-AES-01B (for 1 read head) ; 104770

EUCHNER Evaluation unit CES-AZ-AES-01B (for 1 read head) ; 104770

Evaluation unit CES-AZ-AES-01B (for 1 read head) ; 104770 1 read head can be connected 2 safety outputs (relay contacts with 2 internally connected NO contacts per...

Brand: EUCHNER
Šifra: 104770
Dostupnost: Proveriti dostupnost
Cena na upit
Evaluation unit CES-AZ-AES-01B (for 1 read head) ; 104770
  • 1 read head can be connected
  • 2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
  • Start button and feedback loop can be connected
  • Unicode
  • Plug-in connection terminals
  • Category 4 / PL e according to EN ISO 13849-1

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/1DGUV_ET 20018_ET 20019CCC_2020980305000537_CQC2014010303679509

Workspace

Repeat accuracy R  
according to EN 60947-5-2 max. 10 %

Operating and display elements

LED display  
  Diagnostics LED
  Status LED
  Safety contacts status

Electrical connection values

Fuse  
external (operating voltage UB) 0.25 ... 8 A
Connection cross section  
(plug-in screw/spring terminals) 0.25 ... 2.5 mm²
Operating voltage DC  
UB 21 ... 24 ... 27 V DC regulated, residual ripple<5%
EMC protection requirements Acc. to EN 60947-5-3
Current consumption  
(with relay energized) 150 mA
Current via feedback loop 5 ... 8 ... 10 mA
Degree of contamination (external, according to EN 60947-1) 2
permissible resistance in feedback loop max. 600 Ω
  Inputs: start button S, test input TST
Input voltage  
LOW 0 ... 2 V DC
HIGH 15 ... UB V DC
Input current  
HIGH 5 ... 8 ... 10 mA
  Monitoring outputs: diagnostics DIA, door monitoring output O1
Output type Semiconductor output, p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC
Switching current max. 20 mA
  Safety contacts 13/14, 23/24
Fuse  
external (safety circuit) according to EN 60269-1 6 AgG or 6 A circuit breaker (characteristic B or C)
Output type Relay contacts, floating
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 4 kV
Discrepancy time  
(between the operating points of both relays) max. 25 ms
Utilization category  
DC-12 60 V 0.3 A
AC-12 30 V 6 A
AC-12 60 V 0.3 A
DC-12 30 V 6 A
AC-15 230 V 2 A
DC-13 24 V 3 A
Switching load  
according to c UL us Class 2 max. 30 V AC / Class 2 max. 60 V DC; 120 V AC 3 A / 240 V AC 1.5 A
Switching current  
at switching voltage AC 5 ... 230 V 10 ... 2000 mA
at switching voltage AC/DC 21 ... 60 V 1 ... 300 mA
at switching voltage AC/DC 5 ... 30 V 10 ... 6000 mA

Mechanical values and environment

Connection type plug-in connection terminals, coded
Number of read heads 1 read head can be connected
Ready delay 10 ... 12 s
Switching frequency max. 0.25 Hz
Atmospheric humidity  
not condensing max. 80 % rH
Mounting distance  
laterally to the neighboring device min. 10 mm
Mounting type Mounting rail 35 mm according to DIN EN 60715 TH35
Response time  
Start button response delay (for Manual start operating mode) 200 ... 300 ms
after change in the actuation status max. 210 ms
Start button actuating duration (for Manual Start operating mode) min. 250 ms
Degree of protection IP20
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Dwell time min. 3 s
Material  
Housing Plastic PA6.6
  Safety contacts 13/14, 23/24
Number of safety contacts 2 Relay with internally monitored contacts
Mechanical life  
Operating cycles (relay) 10 x 10⁶

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Number of switching cycles  
≤ 0.1 A at 24 V DC max. 760000 1/y
≤ 1 A at 24 V DC max. 153000 1/y
≤ 3 A at 24 V DC max. 34600 1/y
Diagnostic Coverage (DC) 99 %
Mission time 20 y
  Monitoring of the guard position
Category 4
Performance Level PL e
PFHD 1.9 x 10-8

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measure.

In combination with read head CES-A-LSP-05V-104966, CES-A-LSP-10V-104967, CES-A-LSP-SB-104969, CES-A-LSP-15V-106271 and actuator CES-A-BSP-104970

Switch-on distance  
with center offset m=0 20 mm
Secured switch-off distance sar max. 45 mm
Secured switching distance sao  
with center offset m=0 min. 10 mm
Switching hysteresis 1 ... 4 mm

In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BDN-06-104730

Switch-on distance  
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) 19 mm
Secured switch-off distance sar  
in x or z direction max. 50 mm
in y direction max. 100 mm
Secured switching distance sao  
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) min. 14 mm
Switching hysteresis 4 mm

In combination with read head CES-A-LQA-SC

Mounting distance  
neighboring read heads min. 80 mm

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V

Mounting distance  
neighboring read heads min. 50 mm

In combination with read head CES-A-LQA-SC and actuator CES-A-BBA-071840, CES-A-BCA

Switch-on distance  
for side approach direction (distance in x direction 8 mm) +/- 22 mm
for vertical approach direction (center offset m=0) 15 mm
Secured switch-off distance sar max. 47 mm
Secured switching distance sao  
for side approach direction (distance in x direction 8 mm) min. +/- 18 mm
for vertical approach direction (center offset m=0) min. 10 mm
Switching hysteresis  
for side approach direction (distance in x direction 8 mm) 1 ... 1.8 mm
for vertical approach direction (center offset m=0) 2 ... 3 mm

In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-20

Switch-on distance  
with center offset m=0 9 mm A distance of s = 4 mm must be maintained for a side approach direction.
Secured switch-off distance sar  
with center offset m=0 max. 26 mm
Secured switching distance sao  
with center offset m=0 min. 6 mm
Switching hysteresis  
with center offset m=0 1 ... 1.8 mm

In combination with read head CES-A-LQA-SC and actuator CES-A-BQA

Switch-on distance  
for vertical approach direction (center offset m=0) 23 mm
for side approach direction (distance in x direction 10 mm) +/- 28 mm
Secured switch-off distance sar max. 60 mm
Secured switching distance sao  
for side approach direction (distance in x direction 10 mm) min. +/- 24 mm
for vertical approach direction (center offset m=0) min. 16 mm
Switching hysteresis  
for vertical approach direction (center offset m=0) 2 ... 3 mm
for side approach direction (distance in x direction 10 mm) 1 ... 1.3 mm

In combination with read head CES-A-LMN-SC and actuator CES-A-BDA-18-156935

Actuator distance s  
Minimum distance for side approach direction min. 3 mm
Switch-on distance  
with center offset m=0 9 mm
Secured switch-off distance sar max. 21 mm
Secured switching distance sao  
with center offset m=0 min. 6 mm
Switching hysteresis  
with center offset m=0 0.5 ... 1 mm

In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294

Mounting distance  
neighboring read heads min. 160 mm

In combination with read head CES-A-LMN-SC

Mounting distance  
neighboring read heads min. 20 mm

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-18-156935

Actuator distance s  
Minimum distance for side approach direction min. 5 mm
Switch-on distance  
with center offset m=0 16 mm
Secured switch-off distance sar max. 32 mm
Secured switching distance sao  
with center offset m=0 min. 10 mm
Switching hysteresis  
with center offset m=0 0.5 ... 1.4 mm

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BDA-20

Actuator distance s  
Minimum distance for side approach direction min. 4 mm
Switch-on distance  
with center offset m=0 16 mm
Secured switch-off distance sar max. 33 mm
Secured switching distance sao  
with center offset m=0 min. 11 mm
Switching hysteresis 0.5 ... 2 mm

In combination with read head CES-A-LNN-SC-106601, CES-A-LNN-05V-106602, CES-A-LNN-10V-113294 and actuator CES-A-BBN-106600

Switch-on distance  
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) 15 mm
Secured switch-off distance sar  
in y direction max. 100 mm
in x or z direction max. 50 mm
Secured switching distance sao  
in z direction (with center offset x,y=0), in y direction (with center offset x,z=0) min. 10 mm
Switching hysteresis 1 ... 4 mm

In combination with read head CES-A-LMN-SC and actuator CES-A-BMB

Actuator distance s  
Minimum distance min. 1.2 mm
Switch-on distance  
with center offset m=0 5 mm
Secured switch-off distance sar max. 10 mm
Secured switching distance sao  
with center offset m=0 min. 3.5 mm
Switching hysteresis 0.1 ... 0.3 mm

In combination with read head CES-A-LMN-SC and actuator CES-A-BBA-071840

Switch-on distance  
with center offset m=0 8 mm A distance of s = 3 mm must be maintained for a side approach direction.
Secured switch-off distance sar  
with center offset m=0 max. 25 mm
Secured switching distance sao  
with center offset m=0 min. 5 mm
Switching hysteresis  
with center offset m=0 1 ... 1.8 mm

In combination with read head CES-A-LNA-SC-077715, CES-A-LNA-05P-077806, CES-A-LNA-10P-077807, CES-A-LNA-05V-071845, CES-A-LNA-10V-071846, CES-A-LNA-15V-071847, CES-A-LNA-25V-071975, CES-A-LNA-15P-084682, CES-A-LCA-10V and actuator CES-A-BBA-071840, CES-A-BCA

Actuator distance s  
Minimum distance for side approach direction min. 3 mm
Switch-on distance  
with center offset m=0 15 mm
Secured switch-off distance sar max. 26 mm
Secured switching distance sao  
with center offset m=0 min. 10 mm
Switching hysteresis 0.5 ... 2 mm

Slicni proizvodi:


EUCHNER Evaluation unit CES-AZ-AES-02B (for 2 read heads); 104775

EUCHNER Evaluation unit CES-AZ-AES-02B (for 2 read heads); 104775 2 read heads can be connected 2 safety outputs (relay contacts with 2 internally connected NO contacts
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Read head CES-A-LNA-SC ; 077715

Read head CES-A-LNA-SC, M8 plug connector Cube-shaped design 42 x 25 mm With plug connector M8 Two safety screws M4x14 included
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Read head CES-A-LNN-05V-106602, hard-wired encapsulated cable 5 m, PVC; 106602

Read head CES-A-LNN-...hard-wired encapsulated cable 5 m, PVC, CES-A-LNN-05V-106602 (Order no. 106602) // Cube-shaped design 42 x 25 mm Mounting compatible with
-