EUCHNER Evaluation unit CMS-E-AR ; 099258
Evaluation unit CMS-E-FR, 2 safety contacts, 1 auxiliary contact, 6 monitoring outputs, 1 feedback loop can be connected.. Up to 30 read heads can be connected 2...
Cena na upit
Evaluation unit CMS-E-FR, 2 safety contacts, 1 auxiliary contact, 6 monitoring outputs, 1 feedback loop can be connected..
- Up to 30 read heads can be connected
- 2 safety contacts
- 1 auxiliary contact
- 6 door monitoring outputs
- 1 feedback loop can be connected
- Start automatic/monitored/not monitored
Approvals
Mechanical values and environment
Housing material | Polyamide PA6.6 |
Weight | |
Net | 0,3 kg |
Ambient temperature | 0 ... 55 °C |
Degree of protection | Terminals IP20 / housing IP40 |
Mechanical life | 10 x 106 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Connection | Connection terminals |
Safety contacts 13/14, 23/24 | |
Number of safety contacts | 2 |
Auxiliary contacts 31/32 | |
Number of auxiliary contacts | 1 |
Semiconductor outputs 01 to 06 | |
Number of monitoring outputs | 6 |
Electrical connection ratings
Operating voltage | |
AC/DC | 24 V -10% ... +10% |
Fusing | |
Protection internal (operating voltage UB) | 0,75 A Automatically resetting fuse PTC |
Rated insulation voltage Ui | |
AC | 250 V |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 ... 2,5 mm² |
LED indicator | 1 indicator LED Power, 2 output LEDs and 6 status indicators for the read heads |
Safety contacts 13/14, 23/24 | |
Type of output | Relay contacts, floating |
Switching voltage | |
AC | max.240 V |
Switching current | |
at DC 24V | 10 ... 3000 mA |
Fusing | |
External contact fuse (safety circuit) acc. to EN IEC 60269-1 | 4A gG |
Utilization category according to EN 60947-4-1 | |
Utilization category according to EN 60947-5-1 | |
AC-15 | 0.9A , 240V and 0.9A , 24V |
DC-13 | 1.5A , 24V |
Switching load | |
According to UL class 2 | Input: 24V AC/DC ; output: 30V AC, 24V DC |
Breaking capacity (VA) | max.720 VA |
Risk time according to EN 60947-5-3 | 20 ms |
Auxiliary contacts 31/32 | |
Type of output | Relay contacts, floating |
Switching current | |
at DC 24V | max.1500 mA |
Semiconductor outputs 01 to 06 | |
Type of output | Semiconductor outputs, p-switching |
Switching current | |
at DC 24V | 50 mA Per monitoring output 01 to 06 |
Other
In compliance with | EN ISO 13849-1: 2015; EN ISO 13849-2:2012; EN 50178: 1997; EN 60204-1: 2006/A1: 2009; EN ISO 13850: 2015; EN 14119: 2013; EN 6100-2-6: 2005; EN 6100-6-3: 2007/A1: 2011; EN 60947-5-3: 2013 |
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position | |
Category | |
With more than one read head | 3 |
With one read head | 4 |
Performance Level | |
With one read head | PL e |
With more than one read head | PL d |
PFHD | |
With one read head | 2.5 x 10-8 |
With more than one read head | 1.0 x 10-7 |
Number of switching cycles | |
≤ 0.1A at 24V DC | max.166000 1/Jahr |
≤ 1A at 24V DC | max.70000 1/Jahr |
Mission time | 20 y |
In combination with Read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC and Actuator CMS-M-AC
Operating distance
Center offset | |
At s =3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.31 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |
In combination with Read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-07P, CMS-R-BXI-SC and Actuator CMS-M-BD
Operating distance
Center offset | |
At s =3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.12 mm |
Assured operating distance Sao | |
With center offset m=0 | min.3 mm |
In combination with Read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and Actuator CMS-M-CA
Operating distance
Center offset | |
At s =3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.14 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |
In combination with Read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and Actuator CMS-M-EF
Operating distance
Center offset | |
At s =3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.17 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |
In combination with Read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and Actuator CMS-MH-AA
Operating distance
Center offset | |
At s =3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.20 mm |
Assured operating distance Sao | |
With center offset m=0 | min.10 mm |
In combination with Read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and Actuator CMS-MH-BB
Operating distance
Center offset | |
At s =3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.13 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |
Slicni proizvodi:
EUCHNER Evaluation unit CMS-E-AR ; 085536
Evaluation unit CMS-E-AR, 1 safety contact Magnetically coded safety switches are interlocking devices that are designed to protect people and machines. Compared
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Evaluation unit CMS-E-AR ; 085537
Evaluation unit CMS-E-BR, 1 safety contact, 1 auxiliary contact, 1 feedback loop can be connected.. Four read heads can be connected 1 safety contact 1 auxiliary
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Evaluation unit CMS-E-AR ; 099182
Evaluation unit CMS-E-ER, 2 safety contacts, 1 auxiliary contact, 1 feedback loop can be connected.. Up to 30 read heads can be connected 2 safety contacts 1 auxiliary
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Actuator CMS design B, CMS-M-BH (Order no. 092025)
Actuator CMS design B, CMS-M-BH (Order no. 092025) Cube-shaped version, 36 x 26 mm
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Read Heads CMS ; CMS-R-AZA-01PL-AS1 ; 105090
Non-contact safety switch CMS-R-AZA-01VL-AS1, with connection cable and plug connector M12. Safety switches with integrated read head and integrated evaluation unit.
-
(Trenutno nema na stanju)
Cena na upit