EUCHNER Interlocking module MGB-L0-ARA-AA1A1-S1-L-111941; 111941
Interlocking module MGB-L0-ARA..., without control or indicator, RC18 Interlocking (without guard locking) Can be connected in series with other AR devices (e.g....
Cena na upit
Interlocking module MGB-L0-ARA..., without control or indicator, RC18
- Interlocking (without guard locking)
- Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
- With plug connector RC18
- Unicode
Approvals
Operating and display elements
Occupancy diagram | L0 |
Electrical connection values
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Discrepancy time | |
between FO1A and FO1B | max. 10 ms |
Utilization category | |
DC-13 | 24V 200mA |
Risk time according to EN 60947-5-3 | max. 350 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring outputs OD, OT, OL, OI | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max. 50 mA |
Safety outputs FO1A, FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
Output current | |
per safety output FO1A / FO1B | 1 ... 200 mA |
Test pulse duration | max. 1 ms |
Test pulse interval | min. 100 ms |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... +10% |
Current consumption | |
IUA | max. 10 mA |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... +10% |
Current consumption | |
IUB | max. 80 mA |
Mechanical values and environment
Connection type | Plug connector RC18 |
Installation orientation | Door hinge DIN left |
Switching frequency | 0.25 Hz |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
1 x 10⁶ | |
Degree of protection | IP65 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Monitoring of the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Miscellaneous
Product version number | V4.0.0 |
Slicni proizvodi:
EUCHNER Interlocking module MGB-L0-ARA-AA1A1-S1-L-110953; 110953
Interlocking module MGB-L0-ARA..., without controls or indicators, RC18 Interlocking (without guard locking) Can be connected in series with other AR devices (e.g.
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Interlocking set MGB-L0H-ARA-L-110952; 110952
Interlocking set MGB-L0H-ARA..., without controls or indicators, RC18 Interlocking (without guard locking) Can be connected in series with other AR devices (e.g.
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Interlocking set MGB-L0H-ARA-L-110958; 110958
Interlocking set MGB-L0H-ARA..., with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Interlocking (without guard locking) Can be connected in series with
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Interlocking set MGB-L0H-ARA-L-124259; 124259
Interlocking set MGB-L0H-ARA..., with 2 pushbuttons, incl. label carrier, RC18 Interlocking (without guard locking) Can be connected in series with other AR devices
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Interlocking set MGB-L0HE-ARA-L-110692; 110692
Interlocking set MGB-L0HE-ARA..., with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Interlocking (without guard locking) Can be connected in series with
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Interlocking set MGB-L0HE-ARA-L-111942; 111942
Interlocking set MGB-L0HE-ARA... without controls or indicators, RC18 Interlocking (without guard locking) Can be connected in series with other AR devices (e.g.
-
(Trenutno nema na stanju)
Cena na upit