EUCHNER Locking module MGB-L1-ARA-AL2A1-M-R-121086; 121086
Locking module MGB-L1-ARA-AL2A1-M-R-121086, (guard locking by spring force) with 2 pushbuttons, incl. label carrier; 121086...
Guard locking type
MGB-L1... |
The locking arm is held in the locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked). |
Door stop
A mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier.
LED indicator
The LED indicator indicates all important system and status information.
Monitoring outputs
OD |
ON when the door is closed |
OT |
Bolt tongue inserted into the evaluation module |
OL |
Guard locking solenoid in locked position |
OI |
Diagnostics; there is a fault |
Pushbutton
S2 |
1 NO contact, illuminated |
S3 |
1 NO contact, illuminated |
Lens set
The color of the pushbuttons can be selected using the color cover set included (6 colors). Item no.: 120378 (see Accessories)
Adhesive labels
Devices with adhesive labels have pre-formed recesses. The adhesive labels enclosed (standard size 12.5 x 27 mm) can be affixed in these recesses.
Electrical connection values
Connection cross section | |
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0.25 ... 1.5 mm² |
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0.25 ... 0.75 mm² |
(rigid/flexible) | 0.13 ... 1.5 mm² |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Discrepancy time | |
between FO1A and FO1B | max. 10 ms |
Utilization category | |
DC-13 | 24V 200mA |
Risk time according to EN 60947-5-3 | max. 350 ms |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external | 3 |
Solenoid control input IMP1, IMP2, IMM | |
Test pulse duration | max. 5 ms |
Test pulse interval | min. 100 ms |
Controls and indicators | |
Breaking capacity | max. 0.25 W |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
LED power supply | 24 V DC |
Monitoring outputs OD, OT, OL, OI | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max. 50 mA |
Safety outputs FO1A, FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
per safety output FO1A / FO1B | 1 ... 200 mA |
Test pulse duration | max. 1 ms |
Test pulse interval | min. 100 ms |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... +10% |
Current consumption | |
IUA | max. 375 mA |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... +10% |
Current consumption | |
IUB | max. 80 mA |
Mechanical values and environment
Connection type | Cable entries M20x1.5 |
Installation orientation | Door hinge DIN right |
Switching frequency | 0.25 Hz |
Mechanical life | |
1 x 10⁶ | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
Degree of protection | IP65 |
Ambient temperature | |
at UB = 24V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Control of guard locking | |
Category | 4 |
Performance Level | PL e |
PFHD | 2.8 x 10-9 |
Monitoring of guard locking and the guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Miscellaneous
Slide-in label | |||||||
|
|||||||
Product version number | V4.0.0 | ||||||
Additional feature | Incl. lens set ID No. 120344 |
Slicni proizvodi:
EUCHNER Locking set MGB-L1H-ARA-R-121061; 121061
(Trenutno nema na stanju)
EUCHNER Locking set MGB-L1HE-ARA-R-110220; 110220
(Trenutno nema na stanju)
EUCHNER Locking module MGB-L2-ARA-BA1A1-M-109945; 109945
(Trenutno nema na stanju)
EUCHNER Locking module MGB-L1-ARA-AL3A1-M-R-121130; 121130
(Trenutno nema na stanju)
EUCHNER Locking module MGB-L1-ARA-AN3A1-M-R-121419; 121419
(Trenutno nema na stanju)
EUCHNER MGB-L1HE-ARA-R-121236
(Trenutno nema na stanju)