EUCHNER Locking module MGB-L2-ARA-AM3A1-M-L-121263; 121263

EUCHNER Locking module MGB-L2-ARA-AM3A1-M-L-121263; 121263

Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier Guard locking with guard lock monitoring Can...

Brand: EUCHNER
Šifra: 121263
Dostupnost: Proveriti dostupnost
Cena na upit

Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier

  • Guard locking with guard lock monitoring
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • Emergency stop according to ISO 13850
  • 2 pushbuttons (illuminated)
  • With lens set, 6 pcs.
  • incl. adhesive labels
  • With cable entry
  • Unicode

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-09_

Operating and display elements

Occupancy diagram L1
Item Extras Color Designation1 Number LED Note slide-in label Slide-in label Version Switching element
1 with monitoring contact             Emergency stop 2 PD + 1 NO
2               Illuminated pushbutton 1NO
3               Illuminated pushbutton 1NO

Electrical connection values

Connection cross section  
(rigid/flexible) 0.13 ... 1.5 mm² 
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0.25 ... 0.75 mm²
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 0.25 ... 1.5 mm²
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time  
between FO1A and FO1B max. 10 ms
Utilization category  
DC-13 24V 200mA 
Risk time according to EN 60947-5-3 max. 350 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
  Solenoid control input IMP1, IMP2, IMM
Test pulse duration max. 5 ms
Test pulse interval min. 100 ms
  Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage UA V
Switching current 1 ... 10 mA
LED power supply 24 V DC
  Emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 1 ... 100 mA
LED power supply 24 V DC
  Monitoring outputs OD, OT, OL, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC 
Output current max. 50 mA
  Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
UFO1A /UFO1B LOW 0 ... 1 V DC
UFO1A /UFO1B HIGH UB-2V ... UB V DC 
Output current  
per safety output FO1A / FO1B 1 ... 200 mA
Test pulse duration max. 1 ms
Test pulse interval min. 100 ms
  Power supply UA
Operating voltage DC  
UA 24 V DC -15% ... +10% 
Current consumption  
IUA max. 375 mA 
  Power supply UB
Operating voltage DC  
UB 24 V DC -15% ... +10% 
Current consumption  
IUB max. 80 mA 

Mechanical values and environment

Connection type Cable entries M20x1.5
Installation orientation Door hinge DIN left
Switching frequency 0.25 Hz
Mechanical life  
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
  1 x 10⁶
Degree of protection IP65
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y

Slicni proizvodi:


EUCHNER Locking set MGB-L1H-ARA-L-121414; 121414

Locking set MGB-L1H-ARA... (guard locking by spring force) with 2 pushbuttons, machine stop, incl. label carrier Guard locking with guard lock monitoring Can be
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1H-ARA-L-121422; 121422

Locking set MGB-L1H-ARA... (guard locking by spring force) with 2 pushbuttons, key-operated rotary switch, IP54 Guard locking with guard lock monitoring Can be connected
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L2-ARA-AL2A1-M-L-121174; 121174

Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons, incl. label carrier Guard locking with guard lock monitoring Can be connected
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L2-ARA-BL3A1-M-L-121028; 121028

Locking module MGB-L2-ARA... (guard locking by solenoid force) with 1 pushbutton, emergency stop, incl. label carrier, guard lock monitoring switched off Guard locking
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L2HE-ARA-L-121072; 121072

Locking set MGB-L2HE-ARA... (guard locking by solenoid force) with 2 pushbuttons Guard locking with guard lock monitoring Can be connected in series with other AR
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L2HE-ARA-L-121246; 121246

Locking set MGB-L2HE-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Trenutno nema na stanju)

Cena na upit

1
2
3
Uporedi proizvode Ukloni sve proizvode