EUCHNER Locking module MGB-L2-ARA-BL3A1-M-L-121028; 121028
Locking module MGB-L2-ARA... (guard locking by solenoid force) with 1 pushbutton, emergency stop, incl. label carrier, guard lock monitoring switched off Guard locking...
Cena na upit
Locking module MGB-L2-ARA... (guard locking by solenoid force) with 1 pushbutton, emergency stop, incl. label carrier, guard lock monitoring switched off
- Guard locking with guard lock monitoring (switched off)
- Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
- Emergency stop according to ISO 13850
- 1 pushbuttons (illuminated)
- With lens set, 6 pcs.
- incl. adhesive label
- With cable entry
- Unicode
Approvals
Operating and display elements
Occupancy diagram | L1 |
Item | Extras | Color | Designation1 | Number | LED | Note slide-in label | Slide-in label | Version | Switching element |
---|---|---|---|---|---|---|---|---|---|
1 | with monitoring contact | Emergency stop | 2 PD + 1 NO | ||||||
2 | Illuminated pushbutton | 1NO |
Electrical connection values
Connection cross section | |
(rigid/flexible) | 0.13 ... 1.5 mm² |
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0.25 ... 0.75 mm² |
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0.25 ... 1.5 mm² |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1.5 kV |
Discrepancy time | |
between FO1A and FO1B | max. 10 ms |
Utilization category | |
DC-13 | 24V 200mA |
Risk time according to EN 60947-5-3 | max. 350 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Safety class | III |
Transponder coding | Unicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Solenoid control input IMP1, IMP2, IMM | |
Test pulse duration | max. 5 ms |
Test pulse interval | min. 100 ms |
Controls and indicators | |
Breaking capacity | max. 0.25 W |
Switching voltage | UA V |
Switching current | 1 ... 10 mA |
LED power supply | 24 V DC |
Emergency stop | |
Breaking capacity | max. 0.25 W |
Switching voltage | 5 ... 24 V |
Switching current | 1 ... 100 mA |
LED power supply | 24 V DC |
Monitoring outputs OD, OT, OL, OI | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max. 50 mA |
Safety outputs FO1A, FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
per safety output FO1A / FO1B | 1 ... 200 mA |
Test pulse duration | max. 1 ms |
Test pulse interval | min. 100 ms |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... +10% |
Current consumption | |
IUA | max. 375 mA |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... +10% |
Current consumption | |
IUB | max. 80 mA |
Mechanical values and environment
Connection type | Cable entries M20x1.5 |
Installation orientation | Door hinge DIN left |
Switching frequency | 0.25 Hz |
Mechanical life | |
1 x 10⁶ | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
Degree of protection | IP65 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Emergency stop | |
B10D | |
Emergency stop | 0.13 x 10⁶ |
Slicni proizvodi:
EUCHNER Locking set MGB-L1HE-ARA-L-160590; 160590
Locking set MGB-L1HE-ARA... (guard locking by spring force) with 1 pushbutton, emergency stop, selector switch Guard locking with guard lock monitoring Can be connected
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L2H-ARA-L-121029; 121029
Locking set MGB-L2H-ARA... (guard locking by solenoid force) with 1 pushbutton, emergency stop, incl. label carrier, guard lock monitoring switched off Guard locking
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L2H-ARA-L-121071; 121071
Locking set MGB-L2H-ARA... (guard locking by solenoid force) with 2 pushbuttons Guard locking with guard lock monitoring Can be connected in series with other AR
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking module MGB-L1-ARA-AL2A1-M-L-121067; 121067
Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbutton Guard locking with guard lock monitoring Can be connected in series with other AR
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking module MGB-L1-ARA-AN1A1-M-L-121413; 121413
Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, machine stop, incl. label carrier Guard locking with guard lock monitoring Can be
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L1H-ARA-L-121171; 121171
Locking set MGB-L1H-ARA... (guard locking by spring force) with 2 pushbuttons, incl. label carrier Guard locking with guard lock monitoring Can be connected in series
-
(Trenutno nema na stanju)