EUCHNER Locking set MGB-L1H-ARA-R-111070; 111070

EUCHNER Locking set MGB-L1H-ARA-R-111070; 111070

Locking set MGB-L1H-ARA... (guard locking by spring force) without control or indicator, RC18 Guard locking with guard lock monitoring Can be connected in series...

Brand: EUCHNER
Šifra: 111070
Dostupnost: Proveriti dostupnost
Cena na upit

Locking set MGB-L1H-ARA... (guard locking by spring force) without control or indicator, RC18

  • Guard locking with guard lock monitoring
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • With plug connector RC18
  • Unicode

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-09_

Handle modules MGB-H-AA1A1-R-100464 (Order no. 100464)

Handle modules MGB-H-AA1A1-R-100464  (Order no. 100464)

Mechanical values and environment

Installation orientation Door hinge DIN right
Degree of protection IP65
Ambient temperature -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Product version number V3.0.0

Locking modules MGB-L1-ARA-AA1A1-S1-R-111071 (Order no. 111071)

Locking modules MGB-L1-ARA-AA1A1-S1-R-111071  (Order no. 111071)

Operating and display elements

Occupancy diagram L0

Electrical connection values

Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time  
between FO1A and FO1B max. 10 ms
Utilization category  
DC-13 24V 200mA 
Risk time according to EN 60947-5-3 max. 350 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
  Solenoid control input IMP1, IMP2, IMM
Test pulse duration max. 5 ms
Test pulse interval min. 100 ms
  Monitoring outputs OD, OT, OL, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC 
Output current max. 50 mA
  Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
UFO1A /UFO1B HIGH UB-2V ... UB V DC 
UFO1A /UFO1B LOW 0 ... 1 V DC
Output current  
per safety output FO1A / FO1B 1 ... 200 mA
Test pulse duration max. 1 ms
Test pulse interval min. 100 ms
  Power supply UA
Operating voltage DC  
UA 24 V DC -15% ... +10% 
Current consumption  
IUA max. 375 mA 
  Power supply UB
Operating voltage DC  
UB 24 V DC -15% ... +10% 
Current consumption  
IUB max. 80 mA 

Mechanical values and environment

Connection type Plug connector RC18 
Installation orientation Door hinge DIN right
Switching frequency 0.25 Hz
Mechanical life  
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
  1 x 10⁶
Degree of protection IP65
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
  Control of guard locking
Category 4
Performance Level PL e
PFHD 2.8 x 10-9
  Monitoring of guard locking and the guard position
Category 4
Performance Level PL e
PFHD 3.7 x 10-9

Miscellaneous

Product version number V4.0.0

Slicni proizvodi:


EUCHNER Locking module MGB-L1-ARA-AD4A1-S1-R-110872; 110872

Locking module MGB-L1-ARA... (guard locking by spring force) with 3 pushbuttons, incl. label carrier, RC18 Guard locking with guard lock monitoring Can be connected
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L1-ARA-AF8A1-S1-R-114054; 114054

Locking module MGB-L1-ARA... (guard locking by spring force) with 1 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1HE-ARA-R-110689; 110689

Locking set MGB-L1HE-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1HE-ARA-R-157850; 157850

Locking set MGB-L1HE-ARA... (guard locking by spring force) with 2 pushbuttons, key-operated rotary switch, RC18 Guard locking with guard lock monitoring Can be
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L2-ARA-AP1A1-S1-R-121351; 121351

Locking module MGB-L2-ARA..., (guard locking by solenoid force) with 4 pushbuttons, RC18 Guard locking with guard lock monitoring Can be connected in series with
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L1-ARA-AA1A1-S1-R-111939; 111939

Locking module MGB-L1-ARA... (guard locking by spring force) without controls or indicators, RC18 Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Trenutno nema na stanju)

Cena na upit

1
2
3
Uporedi proizvode Ukloni sve proizvode