Locking set MGB-L1HE-ARA... (guard locking by spring force) without controls or indicators, RC18

  • Guard locking with guard lock monitoring
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • With plug connector RC18
  • With escape release
  • Unicode
  • Release monitoring

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-09_

Escape release MGB-E-A-100465 (Order no. 100465)

Escape release MGB-E-A-100465  (Order no. 100465)

Mechanical values and environment

Installation orientation any
Mechanical life 1 x 10⁶
Ambient temperature -25 ... +55 °C
Material  
Housing Die-cast zinc/stainless steel, powder-coated

Miscellaneous

Product version number V2.0.0

Locking modules MGB-L1-ARA-AA1A1-S1-L-111943 (Order no. 111943)

Locking modules MGB-L1-ARA-AA1A1-S1-L-111943  (Order no. 111943)

Operating and display elements

Occupancy diagram L0

Electrical connection values

Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time  
between FO1A and FO1B max. 10 ms
Utilization category  
DC-13 24V 200mA 
Risk time according to EN 60947-5-3 max. 350 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
  Solenoid control input IMP1, IMP2, IMM
Test pulse duration max. 5 ms
Test pulse interval min. 100 ms
  Monitoring outputs OD, OT, OL, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC 
Output current max. 50 mA
  Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
UFO1A /UFO1B LOW 0 ... 1 V DC
UFO1A /UFO1B HIGH UB-2V ... UB V DC 
Output current  
per safety output FO1A / FO1B 1 ... 200 mA
Test pulse duration max. 1 ms
Test pulse interval min. 100 ms
  Power supply UA
Operating voltage DC  
UA 24 V DC -15% ... +10% 
Current consumption  
IUA max. 375 mA 
  Power supply UB
Operating voltage DC  
UB 24 V DC -15% ... +10% 
Current consumption  
IUB max. 80 mA 

Mechanical values and environment

Connection type Plug connector RC18 
Installation orientation Door hinge DIN left
Switching frequency 0.25 Hz
Mechanical life  
  1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Degree of protection IP65
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
  Control of guard locking
Category 4
Performance Level PL e
PFHD 2.8 x 10-9
  Monitoring of guard locking and the guard position
Category 4
Performance Level PL e
PFHD 3.7 x 10-9

Miscellaneous

Product version number V4.0.0

Handle modules MGB-H-AA1A3-L-111158 (Order no. 111158)

Handle modules MGB-H-AA1A3-L-111158  (Order no. 111158)

Mechanical values and environment

Installation orientation Door hinge DIN left
Degree of protection IP65
Ambient temperature -20 ... +55 °C

Slicni proizvodi:


EUCHNER Locking set MGB-L1H-ARA-L-111073; 111073

Locking set MGB-L1H-ARA... (guard locking by spring force) without control or indicator, RC18 Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1HE-ARA-L-119760; 119760

Locking set MGB-L1HE-ARA..., (guard locking by spring force) with 3 pushbutton, RC18 Guard locking with guard lock monitoring Can be connected in series with other
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L2-ARA-AL2A1-S1-L-121113; 121113

Locking module MGB-L2-ARA... (guard locking by solenoid force) with 2 pushbuttons, incl. label carrier, RC18 Guard locking with guard lock monitoring Can be connected
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L2HE-ARA-L-121195; 121195

Locking set MGB-L2HE-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L1-ARA-AA8A1-S1-L-111654; 111654

Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, incl. label carrier, RC18 Guard locking with guard lock monitoring Can be connected
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1H-ARA-L-111022; 111022

Locking set MGB-L1H-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Can be connected in
-
Need to order

(Trenutno nema na stanju)

Cena na upit

1
2
3
Uporedi proizvode Ukloni sve proizvode