EUCHNER Locking set MGB-L2H-ARA-R-121011; 121011

EUCHNER Locking set MGB-L2H-ARA-R-121011; 121011

Locking set MGB-L2H-ARA... (guard locking by solenoid force) with 1 pushbutton, incl. label carrier, guard lock monitoring switched off Guard locking with guard...

Brand: EUCHNER
Šifra: 121011
Dostupnost: Proveriti dostupnost
Cena na upit

Locking set MGB-L2H-ARA... (guard locking by solenoid force) with 1 pushbutton, incl. label carrier, guard lock monitoring switched off

  • Guard locking with guard lock monitoring (switched off)
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • 1 pushbuttons (illuminated)
  • With lens set, 6 pcs.
  • incl. adhesive label
  • With cable entry
  • Unicode

Approvals

c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-09_

Handle modules MGB-H-AA1A1-R-100464 (Order no. 100464)

Handle modules MGB-H-AA1A1-R-100464  (Order no. 100464)

Mechanical values and environment

Installation orientation Door hinge DIN right
Degree of protection IP65
Ambient temperature -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Miscellaneous

Product version number V3.0.0

Locking modules MGB-L2-ARA-BK5A1-M-R-121010 (Order no. 121010)

Locking modules MGB-L2-ARA-BK5A1-M-R-121010  (Order no. 121010)

Operating and display elements

Occupancy diagram L1
Item Extras Color Designation1 Number LED Version Note slide-in label Switching element Slide-in label
2           Illuminated pushbutton   1NO  

Electrical connection values

Connection cross section  
(rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0.25 ... 0.75 mm²
(rigid/flexible) 0.13 ... 1.5 mm² 
(rigid/flexible) with cable end sleeve according to DIN 46 228/1 0.25 ... 1.5 mm²
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1.5 kV
Discrepancy time  
between FO1A and FO1B max. 10 ms
Utilization category  
DC-13 24 V 200 mA 
Risk time according to EN 60947-5-3 max. 350 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3
  Solenoid control input IMP1, IMP2, IMM
Test pulse duration max. 5 ms
Test pulse interval min. 100 ms
  Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage UA V
Switching current 1 ... 10 mA
LED power supply 24 V DC
  Monitoring outputs OD, OT, OL, OI
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC 
Output current max. 50 mA
  Safety outputs FO1A, FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
UFO1A /UFO1B HIGH UB-2V ... UB V DC 
UFO1A /UFO1B LOW 0 ... 1 V DC
Output current  
per safety output FO1A / FO1B 1 ... 200 mA
Test pulse duration max. 1 ms
Test pulse interval min. 100 ms
  Power supply UA
Operating voltage DC  
UA 24 V DC -15% ... +10% 
Current consumption  
IUA max. 375 mA 
  Power supply UB
Operating voltage DC  
UB 24 V DC -15% ... +10% 
Current consumption  
IUB max. 80 mA 

Mechanical values and environment

Connection type Cable entries M20x1.5
Installation orientation Door hinge DIN right
Switching frequency 0.25 Hz
Mechanical life  
  1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Degree of protection IP65
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Housing Fiber glass reinforced plastic; nickel-plated die-cast zinc; stainless steel
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

 

Slicni proizvodi:


EUCHNER Locking set MGB-L1HE-ARC-R-121004; 121004

Locking set MGB-L1HE-ARC... (guard locking by spring force) with 1 pushbutton, multicode Guard locking with guard lock monitoring Can be connected in series with
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L2-ARA-BL3A1-M-R-121024; 121024

Locking module MGB-L2-ARA... (guard locking by solenoid force) with 1 pushbutton, emergency stop, incl. label carrier, guard lock monitoring switched off Guard locking
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L1-ARA-AJ2A1-M-109314; 109314

Locking module MGB-L1-ARA... (guard locking by spring force) with 1 pushbutton, selector switch and emergency stop Guard locking with guard lock monitoring Can be
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L1-ARA-AJ4A1-M-R-122235; 122235

Locking module MGB-L1-ARA..., (guard locking by spring force) with 3 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L1-ARA-AN6A1-M-R-160587; 160587

Locking module MGB-L1-ARA... (guard locking by spring force) with 1 pushbutton, selector switch and emergency stop Guard locking with guard lock monitoring Can be
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1H-ARA-R-105783; 105783

Locking set MGB-L1H-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Trenutno nema na stanju)

Cena na upit

1
2
3
Uporedi proizvode Ukloni sve proizvode