EUCHNER MGB-L2B-PNC-L-123012 (Order no. 123012)
Evaluation module and bus module MGB-L2...-PN (guard locking by solenoid force) with 4 control elements, push-pull plug...
Cena na upit
Evaluation module and bus module MGB-L2...-PN (guard locking by solenoid force) with 4 control elements, push-pull plug
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 3 illuminated pushbuttons
- Push-pull plug
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Multicode
Approvals





Workspace
Rated operating distances Sn | 20 mm |
Operating and display elements
Occupancy diagram | |
L0 | |
B1 |
Item | Color | Extras | Switching element | Version | Slide-in label | Note slide-in label | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
90 | white | printed | 1NO | Illuminated pushbutton | |||||
91 | RGB | printed | 1NO | Illuminated pushbutton | |||||
92 | Blue | printed | 1NO | Illuminated pushbutton | |||||
94 | with adhesive ring | 2 PD | Emergency stop illuminated |
Electrical connection values
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 600 mA |
Transponder coding | Multicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Mechanical values and environment
Connection type | |
for enabling switch | Plug connector RC12 |
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 |
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 |
Push-pull power | |
Push-pull power | |
Installation orientation | Door hinge DIN left |
Switching frequency | 0.25 Hz |
Mechanical life | |
1 x 10⁶ | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
Response time | |
Emergency stop / machine stop | max. 250 ms Turn-off time |
Door position | max. 550 ms Turn-off time |
Bolt position | max. 550 ms Turn-off time |
Guard locking | max. 550 ms Turn-off time |
Enabling switch | max. 250 ms Turn-off time |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Enabling switch evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | 3 | 4.07x10-8 | 4 | 20 y |
Monitoring of guard locking | PL e | 3 | 4.07x10-8 | 4 | 20 y |
Evaluating safety signals | PL e | 3 | 4.1x10-8 | 4 | 20 y |
Applies to all additionally included safety functions such as EMERGENCY STOP, enabling switch, etc. |
B10D | Mission time | |
---|---|---|
Emergency stop | 0.13x106 | 20 y |
Miscellaneous
Product version number | V3.30.10 |
Interface
Bus data protocol | Profinet (IEC 61158 type 10) |
Safety data protocol | Profisafe (IEC 61784-3-3) |
Date interface | |
Ethernet |
Slicni proizvodi:
EUCHNER Locking set MGB-L1H-APA-L-110588; 110588
Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, incl. label carrier, M12 for enabling switch Guard locking with guard lock monitoring
-

(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking module MGB-L2-APA-AC6A1-S1-L-110501; 110501
Locking module MGB-L2-APA.., (guard locking by solenoid force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-

(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking module MGB-L1-ARA-AM5A1-S1-L-121217; 121217
Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-

(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L2...-PN (guard locking by solenoid force) with 5 control elements, 7/8'' and M12 plugs, MGB-L2HEB-PNA-L-161484
Guard locking with guard lock monitoring Emergency stop according to ISO 13850, illuminated 4 illuminated pushbuttons including adhesive labels Connection via 7/8"
-

(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L1H-APA-L-114238; 114238
Locking set MGB-L1H-APA..., (guard locking by spring force) with 3 push buttons, M12 for enabling switch, RC18 Guard locking with guard lock monitoring 3 pushbuttons
-

(Trenutno nema na stanju)
Cena na upit
EUCHNER MGB-L1HB-PNA-R-113230 (Order no. 113230)
Locking set MGB-L1...-PN (guard locking by spring force) with 4 control elements, 7/8" and M12 plugs Guard locking with guard lock monitoring With key-operated
-

(Trenutno nema na stanju)
Cena na upit