Non-contact safety switch CET-AP-..., M12, with wire front release (bowden), for connection to decentralized peripheral systems Safety switch with guard locking...

Brand: EUCHNER
Šifra: 161577
Dostupnost: Proveriti dostupnost
Cena na upit

Non-contact safety switch CET-AP-..., M12, with wire front release (bowden), for connection to decentralized peripheral systems

  • Safety switch with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Connection to decentralized peripheral systems (e.g. ET200pro) via Y-distributor
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • Unicode
  • Door monitoring output
  • Indication of the door position by LED
  • Wire front release (bowden), 3 m, automatic return
  • Approach direction A (delivery state)

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/8

Workspace

Repeat accuracy R  
according to EN 60947-5-2 10 %

Electrical connection values

Fuse  
external (operating voltage UB) 0.25 ... 8 A
external (solenoid operating voltage UCM) 0.5 ... 8 A
Power consumption  
Solenoid 11 W
Connecting cable 30V DC, 2A 
Operating voltage DC  
LED 24 V DC -15% V DC ... +10% V DC
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category  
DC-13 24 V 200 mA 
Solenoid operating voltage DC  
UCM 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 400 ms
Switching load  
according to UL 24V DC, Class 2 
Safety class  
EN IEC 61140 III
Current consumption  
IB 80 mA
ICM 450 mA
Test pulse duration max. 0.3 ms 
Degree of contamination (external, according to EN 60947-1) 3
  Monitoring output OUT D
Output type p-switching, short circuit-proof
Output voltage  
OUT D 0.8xUB ... UB V DC
Switching current  
OUT D 1 ... 50 mA
Switching delay from state change max. 700 ms
  Safety outputs OA / OB
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage  
LOW U(OA,OB) 0 ... 1 V DC
HIGH U(OA,OB) UB-1.5V ... UB V DC
Discrepancy time  
both safety outputs max. 10 ms
Turn-on time 400 ms
Off-state current Ir max. 0.25 mA
Risk time according to EN 60947-5-3  
Single device  
Switching current  
per safety output OA / OB 1 ... 200 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 2 plug connector M12, 5-pin
Ready delay 1 s
Installation orientation any 
Switching frequency max. 0.5 Hz
Degree of freedom X ±5 mm
Degree of freedom Y ±5 mm
Degree of freedom Z ±4 mm
Mechanical life 2 x 10⁶
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67 
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Ramp Stainless steel
Safety switch housing Die-cast aluminum
Locking force Fmax 6500 N
Locking force FZh 5000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
  Monitoring of guard locking and the guard position
Category  
Any installation orientation 4
Performance Level PL e
PFHD  
Any installation orientation 3.1 x 10-9

Miscellaneous

C number  
C2509 OUTD on X2.2 and wire front release (bowden)
The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Slicni proizvodi:


EUCHNER Non-contact safety switch CET3-AP-CRA-CH-50F-SA-C2312-157287; 157287

Non-contact safety switch CET-AP-..., M12 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Short circuit monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Non-contact safety switch CET3-AP-CRA-AH-50F-SI-C2438-124594; 124594

Non-contact safety switch CET-AP-..., with escape release, for connection to decentralized peripheral systems Safety switch with guard locking and integrated evaluation
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Non-contact safety switch CET3-AP-CRA-AH-50X-SF-161524; 161524

Non-contact safety switch CET-AP-..., M12 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Short circuit monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Non-contact safety switch CET3-AP-CRA-AH-50X-SI-111346; 111346

Non-contact safety switch CET-AP-..., for connection to decentralized peripheral systems Safety switch with guard locking and integrated evaluation electronics Locking
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Non-contact safety switch CET3-AP-CRA-AH-50X-SI-C2290-121367; 121367

Non-contact safety switch CET-AP-..., M12, with wire front release (bowden), for connection to decentralized peripheral systems Safety switch with guard locking
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Non-contact safety switch CET3-AP-CRA-AH-50X-SI-C2438-124589; 124589

Non-contact safety switch CET-AP-..., for connection to decentralized peripheral systems Safety switch with guard locking and integrated evaluation electronics Locking
-
Need to order

(Trenutno nema na stanju)

Cena na upit

1
2
3
Uporedi proizvode Ukloni sve proizvode