EUCHNER Non-contact safety switches CES-I-AP-M-C04-U05-117328; 117328

EUCHNER Non-contact safety switches CES-I-AP-M-C04-U05-117328; 117328

Non-contact safety switches CES-I-AP-.- C04-…, flying lead Safety switch with integrated evaluation electronics No series connection Short circuit monitoring...

Brand: EUCHNER
Šifra: 117328
Dostupnost: Proveriti dostupnost
Cena na upit

Non-contact safety switches CES-I-AP-.- C04-…, flying lead

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • Three active faces
  • Connecting cable PUR, 5 m, flying lead
  • Multicode
  • Monitoring output OD

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1ECOLAB__

Workspace

Repeat accuracy R  
according to EN 60947-5-2 <= 10

Electrical connection values

Fuse  
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC  
UB 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV 
Turn-on time  
Safety outputs max. 300 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Safety class III
Current consumption  
no load on outputs max. 35 mA
Degree of contamination (external, according to EN 60947-1) 3
  Monitoring output OD
Output type p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC
Switching current max. 50 mA
  Safety outputs FO1A / FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
HIGH U(FO1A) / U(FO1B) UB-1.5V ... UB V DC 
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
rated conditional short-circuit current 100 A
Discrepancy time max. 10 ms
Utilization category  
DC-13 24 V 150 mA 
Off-state current Ir max. 0.25 mA
Switching current  
per safety output 1 ... 150 mA
Test pulse duration max. 0.3 ms 
Test pulse interval min. 100 ms

Mechanical values and environment

Connection type Connecting cable PUR, length 5 m
Tightening torque  
Fixing screws max. 0.8 Nm
Ready delay 0.5 s
Dynamic bending radius 10 x cable diameter
Static bending radius 5 x cable diameter
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance  
between 2 switches or 2 actuators min. 80 mm
Mounting type Surface mounting on metal
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67
Cable ambient temperature (dynamic) -25 ... +65 °C
Cable ambient temperature (static) -30 ... +65 °C
Material  
Housing Plastic, PBT
Rubber support NBR 80 ±5 Shore

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

  PL Maximum SIL PFHD Category Mission time
Monitoring of the guard position PL e - 4.1x10-9 4 20 y

 

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures
Additional feature Rubber support included

In combination with actuator CES-A-BDN-06-104730

Switch-on distance  
Installation position A or B (front side) 19 mm
Installation position C or D (broad side) 15 mm
Secured switch-off distance sar  
in y direction max. 60 mm
in x/z direction max. 40 mm
Secured switching distance sao  
Installation position A or B (front side) min. 14 mm
Installation position C or D (broad side) min. 10 mm
Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BBN-C04-115271, CES-A-BBN-C04-EX-137527

Switch-on distance  
Installation position C or D (broad side) 11 mm
Installation position A or B (front side) 15 mm
Secured switch-off distance sar  
in x/z direction max. 40 mm
in y direction max. 60 mm
Secured switching distance sao  
Installation position C or D (broad side) min. 6 mm
Installation position A or B (front side) min. 10 mm
Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BDN-06-161742


Slicni proizvodi:


EUCHNER Non-contact safety switches CES-I-AP-U-C04-U10-116504; 116504

Non-contact safety switches CES-I-AP-.- C04-…, flying lead Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Non-contact safety switches CES-I-AP-U-C04-U20-116505; 116505

Non-contact safety switches CES-I-AP-.- C04-…, flying lead Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Non-contact safety switch CES-AP-CL2-AH-L05-105603; 105603

Non-contact safety switch CES-AP-CL2-..., flying lead, PVC Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Non-contact safety switch CES-AP-CL2-AH-L10-106192; 106192

Non-contact safety switch CES-AP-CL2-..., flying lead, PVC Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Non-contact safety switch CES-AP-CR2-AH-SF-105295; 105295

Non-contact safety switch CES-AP-CR2-... , with latching connection Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Non-contact safety switch CES-AP-CR2-CH-L05-105600; 105600

Non-contact safety switch CES-AP-CR2-..., flying lead, PVC Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety
-
Need to order

(Trenutno nema na stanju)

Cena na upit

1