EUCHNER Safety switch STP3A-2131A024M; 091493
Safety switch STP with door monitoring contact Actuating head made of metal Auxiliary release on the front With door monitoring contact...
Cena na upit
Safety switch STP with door monitoring contact
- Actuating head made of metal
- Auxiliary release on the front
- With door monitoring contact
Approvals
Electrical connection values
Power consumption | 8 W |
Connection cross section | 0.34 ... 1.5 mm² |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
DC-13 | 4 A 24 V |
AC-15 | 4 A 230 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Approach direction | A |
Connection type | |
3 x | M20 x 1.5 |
Number of door position NC contacts | 1 |
Number of guard lock monitoring NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Extraction force | 30 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 35 N |
Installation orientation | any |
Insertion depth | 24.5 mm |
Mechanical life | 1 x 10⁶ |
Retention force | 20 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +55 °C |
Material | |
Contact | Silver alloy, gold flashed |
Housing | Reinforced thermoplastic |
Locking force Fmax | 2500 N |
Locking force FZh | 2000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Control of guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the guard position | |
B10D | 5 x 10⁶ |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
In combination with actuator ACTUATOR-S-GT-SN
Overtravel | 5 mm |
Slicni proizvodi:
EUCHNER Safety switch STP3A-4141A024L024M; 112093
Safety switch STP with door monitoring contact Actuating head made of metal Auxiliary release on the front With door monitoring contact With LED function displa
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Safety switch STP4A-4121A024SR11; 099301
Safety switch STP, plug connector SR11, with door monitoring contact Actuating head made of metal Auxiliary release on the front With door monitoring contact
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Safety switch STP-TW-3A-4141AC024M; 100746
Safety switch STP-TWIN with door monitoring contact Two actuating heads made of metal Simultaneous monitoring of two safety doors Auxiliary release on the front
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Safety switch STP-TW-3A-4141AC024SEM4AS1; 102354
Safety switch STP-TWIN ASi, plug connector M12 (closed-circuit current principle) Two actuating heads made of metal Auxiliary release on the front With plug connector
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Safety switch STP2A-528A024M; 099855
Safety switch STP without door monitoring contact Actuating head made of metal Auxiliary release on the front Without door monitoring contact
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Safety switch STP2A-538A024M; 092260
Safety switch STP without door monitoring contact Actuating head made of metal Auxiliary release on the front Without door monitoring contact
-
(Trenutno nema na stanju)
Cena na upit