Electrical connection values
Power consumption | 8 W |
Connection cross section | 0.34 ... 1.5 mm² |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 2.5 kV |
Utilization category | |
DC-13 | 4 A 24 V |
AC-15 | 4 A 50 V |
Short circuit protection according to IEC 60269-1 | 4A gG |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Solenoid duty cycle | 100 % |
Switching voltage | |
min. at 10 mA | 12 V |
Switching current | |
min. at 24 V | 1 mA |
thermal rated current Ith | 4 A |
Mechanical values and environment
Approach speed | max. 20 m/min |
Approach direction | A |
Connection type | |
3 x | M20 x 1.5 |
Number of door position NC contacts | 1 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Extraction force | 30 N |
Actuation frequency | max. 1200 1/h |
Actuating force | 35 N |
Installation orientation | any |
Insertion depth | 24.5 mm |
Mechanical life | 1 x 10⁶ |
Retention force | 20 N |
Switching principle | Slow-action switching contact |
Degree of protection | IP67 |
Ambient temperature | -20 ... +55 °C |
Material | |
Housing | Reinforced thermoplastic |
Contact | Silver alloy, gold flashed |
Locking force Fmax | 2500 N |
Locking force FZh | 2000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Control of guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the guard position | |
B10D | 5 x 10⁶ |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
B10D | Mission time | |
---|---|---|
Monitoring of the guard position | 5x106 | 20 y |
Important! Values valid at DC-13 100 mA/24V |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
Miscellaneous
C number | |
C1993 | Escape release long |
In combination with actuator ACTUATOR-S-GT-SN
Overtravel | 5 mm |
Slicni proizvodi:
EUCHNER Safety switch STP1A-538A024M; 092258
Safety switch STP without door monitoring contact Actuating head made of metal Auxiliary release on the front Without door monitoring contact
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Safety switch STP1D-538A024L024M; 092489
Safety switch STP without door monitoring contact Actuating head made of metal Auxiliary release on the front Without door monitoring contact With pre-assembled
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Safety switch STP3A-4121A024SR11; 096318
Safety switch STP, plug connector SR11, with door monitoring contact Actuating head made of metal Auxiliary release on the front With door monitoring contact
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Safety switch STP4A-2131A110M; 097754
Safety switch STP with door monitoring contact Actuating head made of metal Auxiliary release on the front With door monitoring contact
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Safety switch STP-TW-3A-2131AC024M-S1; 098827
Safety switch STP-TWIN with door monitoring contact Two actuating heads made of metal Simultaneous monitoring of two safety doors Auxiliary release on the front
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Safety switch STP-TW-3A-2131AC024SR11; 106547
Safety switch STP-TWIN, plug connector SR11, with door monitoring contact Two actuating heads made of metal Simultaneous monitoring of two safety doors Auxiliary
-
(Trenutno nema na stanju)
Cena na upit