EUCHNER Transponder-coded safety switch CTM-LBI-BP-U-AZ-SA-166089; 166089
Transponder-coded safety switch CTM-LBI-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with...
Cena na upit
Transponder-coded safety switch CTM-LBI-BP, M12
- Safety switch with guard locking and integrated evaluation electronics
- Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Bistable guard locking
- Category 4 / PL e according to EN ISO 13849-1
- Actuating force 20 N
- Extraction force 18 N
- Retention force 5 N
- Plug connector M12, 8-pin
- Auxiliary release
- Unicode
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection values
Fuse | |
external (operating voltage UB) | 0.7 ... 8 A |
Power consumption | |
at max. switching frequency | 3 W |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
Discrepancy time | |
both safety outputs | max. 10 ms Acc. to EN 60947-5-3 |
Turn-on time | max. 400 ms |
Solenoid duty cycle | 100 % |
Off-state current Ir | max. 0.25 mA |
Risk time according to EN 60947-5-3 | max. 200 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Switching load | DC 24V, UL Class 2 |
Safety class | |
EN IEC 61140 | III |
Test pulse duration | max. 0.3 ms |
Test pulse interval | 100 ms |
Degree of contamination (external, according to EN 60947-1) | |
Industry | 3 |
Solenoid IMP | |
Input voltage | |
Guard locking not active (open) | 20.4 ... 26.4 V DC |
Guard locking active (closed) | 0 ... 5 V DC |
Current consumption | |
Guard locking not active (open) | 20 ... 50 mA |
Diagnostic monitoring output OI, door position monitoring output/communication OD/C, guard lock monitoring output OL | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Switching current | 1 ... 50 mA |
Safety outputs FO1A / FO1B | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
Discrepancy time | |
both safety outputs | max. 10 ms Acc. to EN 60947-5-3 |
Turn-on time | max. 400 ms |
Utilization category | |
DC-13 | 24 V 150 mA |
Off-state current Ir | max. 0.25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max. 200 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Electrical switching frequency | max. 0.25 Hz |
Switching current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Test pulse duration | max. 0.3 ms |
Test pulse interval | 100 ms |
Operating voltage UB | |
Operating voltage DC | |
UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
Current consumption | |
IUB at operating voltage UB = 24 V | max. 500 mA |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | Plug connector M12, 8-pin |
Extraction force | 18 N |
Ready delay | 5.5 s |
Actuating force | 20 N |
Installation orientation | any |
Switching frequency | max. 0.25 Hz |
Mechanical life | 1 x 10⁶ |
Overtravel | 2 mm |
Retention force | 5 N |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65/IP67 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +60 °C |
Material | |
Seals | Fluorinated rubber (FKM) |
Safety switch housing | Reinforced thermoplastic |
Locking force Fmax | 1300 N |
Locking force FZh | 1000 N |
Guard locking principle | BiState |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Control of guard locking | |
Category | 3 |
Performance Level | PL d |
PFHD | 1.03 x 10 -7 |
Monitoring of guard locking | |
Category | 4 |
Slicni proizvodi:
EUCHNER Transponder-coded safety switch CTM-C2-BP-HC-FLX-AZ-SA-170491; 170491
Transponder-coded safety switch CTM-C2-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Transponder-coded safety switch CTM-CBI-BP-HC-FLX-AZ-SA-170490; 170490
Transponder-coded safety switch CTM-CBI-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Transponder-coded safety switch CTM-LBI-BP-M-AZ-SA-166088; 166088
Transponder-coded safety switch CTM-LBI-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Transponder-coded safety switch CTM-LBI-BP-M-AZ-SA-166090; 166090
Transponder-coded safety switch CTM-LBI-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Transponder-coded safety switch CTM-LBI-BP-U-AZ-SA-166087; 166087
Transponder-coded safety switch CTM-LBI-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER CTP-L1-AR-M-HA-AE-SH ; 123374
Safety switch with guard locking and safe guard lock monitoring Integrated CES-AR electronics Safety category 4 and PL e according to EN ISO 13849-1 Compatible mounting
-
(Trenutno nema na stanju)
Cena na upit