Transponder-coded safety switch CTP-AP, M12, ATEX ATEX version Suitable for use in zones 2 and 22 (gases and dusts) Safety switch with guard locking and integrated...
Cena na upit
Transponder-coded safety switch CTP-AP, M12, ATEX
- ATEX version
- Suitable for use in zones 2 and 22 (gases and dusts)
- Safety switch with guard locking and integrated evaluation electronics
- With escape release
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M12
- Unicode
- Door monitoring output OD
- Guard lock monitoring output OL
- Approach directions A, B and C (delivery state)
Approvals
Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection values
Fuse | |
external (operating voltage UB) | 0.25 ... 8 A |
external (solenoid operating voltage IMP) | 0.5 ... 8 A |
Power consumption | 6 W |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
Operating voltage DC | |
UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Utilization category | |
DC-13 | 24 V 150 mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV |
Solenoid duty cycle | 100 % |
Switching load | |
according to UL | 24V DC, Class 2 |
Safety class | |
EN IEC 61140 | III |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 100 ms |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OD, OL | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Switching current | 1 ... 50 mA |
Safety outputs FO1A / FO1B | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
Discrepancy time | |
both safety outputs | max. 10 ms Acc. to EN IEC 60947-5-3 |
Turn-on time | max. 400 ms |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | 1 plug connector M12, 8-pin |
Extraction force | 20 N |
Ready delay | max. 1 s |
Actuating force | 10 N |
Installation orientation | any |
Switching frequency | max. 0.5 Hz |
Mechanical life | 1 x 10⁶ |
Overtravel | 5 mm |
Retention force | 20 N |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP65/IP66 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Material | |
Switch head cover | Die-cast zinc |
Mounting plate | Aluminum |
Protective plate | Stainless steel |
Safety switch housing | Reinforced thermoplastic |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Mission time | 20 y |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10 -9 |
Miscellaneous
Explosion protection | |
incl. protective plate and mounting plate | II3G Ex ec IIC T4 Gc X / II3D Ex tc IIIC T110°C Dc X |
The following applies to the approval according to UL | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Additional feature | Escape release actuated by pushing |
Slicni proizvodi:
EUCHNER Transponder-coded safety switch CTP-L1-AP-U-HA-AE-SA-126912; 126912
Transponder-coded safety switch CTP-AP, M12, with escape release Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Transponder-coded safety switch CTP-L1-AP-U-HA-AE-SH-123375; 123375
Transponder-coded safety switch CTP-AP, M23, with escape release Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Transponder-coded safety switch CTP-L1-AP-U-HA-AE-SII-127640; 127640
Transponder-coded safety switch CTP-AP, 2 x M12, with escape release Safety switch with guard locking and integrated evaluation electronics Direct connection to
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Transponder-coded safety switch CTP-L2-AP-M-HA-AZ-SA-124729; 124729
Transponder-coded safety switch CTP-AP, M12 Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring 2 safety outputs (semiconductor
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Transponder-coded safety switch CTP-L2-AP-M-HA-AZ-SH-123371; 123371
Transponder-coded safety switch CTP-AP, M23 Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring 2 safety outputs (semiconductor
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Transponder-coded safety switch CTP-L2-AP-U-HA-AE-SA-136841; 136841
Transponder-coded safety switch CTP-AP, M12, with escape release Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring
-
(Trenutno nema na stanju)
Cena na upit