EUCHNER Transponder-coded safety switch CTP-L2-AP-U-HA-AZE-SH-158402; 158402

EUCHNER Transponder-coded safety switch CTP-L2-AP-U-HA-AZE-SH-158402; 158402

Transponder-coded safety switch CTP-AP, M23, 2 pushbuttons (extended) Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring...

Brand: EUCHNER
Šifra: 158402
Dostupnost: Proveriti dostupnost
Cena na upit

Transponder-coded safety switch CTP-AP, M23, 2 pushbuttons (extended)

  • Safety switch with guard locking and integrated evaluation electronics
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • 2 pushbuttons (illuminated)
  • With plug connector M23
  • Unicode
  • Door monitoring output
  • Approach directions A, B and C (delivery state)

Approvals

EAC_RU C-DE.MO05.B.00971/20TUEV Süd München_M6A 040393 0040 Rev. 00c_UL_us_E155795_3/11FCC_2AJ58-05_

Workspace

Repeat accuracy R  
according to EN 60947-5-2 10 %

Operating and display elements

Item Extras Color Designation1 Number LED Switching element Note slide-in label Version Slide-in label
2           1NO   Illuminated pushbutton  
3           1NO   Illuminated pushbutton  

Electrical connection values

Fuse  
external (solenoid operating voltage IMP) 0.5 ... 8 A
external (operating voltage UB) 0.25 ... 8 A
Power consumption 6 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage DC  
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category  
DC-13 24 V 150 mA 
Solenoid operating voltage DC  
UIMP 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV
Solenoid duty cycle 100 %
Switching load  
according to UL 24V DC, Class 2 
Safety class  
EN IEC 61140 III
Current consumption  
IIMP 400 mA
IUB 40 mA
Test pulse duration max. 0.3 ms 
Test pulse interval min. 100 ms
Degree of contamination (external, according to EN 60947-1) 3
  Controls and indicators
Operating voltage UB V
Operating current 1 ... 50 mA
Power supply  
LED 24 V
Current consumption  
LED 10 mA
  Monitoring output OD, OI, OL
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Switching current 1 ... 50 mA
  Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage  
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
Discrepancy time  
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 400 ms
Off-state current Ir max. 0.25 mA
Switching current  
per safety output FO1A / FO1B 1 ... 150 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 1 plug connector M23, 19-pin, RC18
Extraction force 20 N
Ready delay max. 1 s
Actuating force 10 N
Installation orientation any
Switching frequency max. 0.5 Hz
Mechanical life 1 x 10⁶
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 
Ambient temperature  
at UB = 24 V DC -20 ... +55 °C
Material  
Switch head cover Die-cast zinc
Safety switch housing Reinforced thermoplastic
Locking force Fmax 3900 N
Locking force FZh 3000 N 
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Category 4

Slicni proizvodi:


EUCHNER Transponder-coded safety switch CTP-L1-AP-U-HA-AE-SA-126912; 126912

Transponder-coded safety switch CTP-AP, M12, with escape release Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Transponder-coded safety switch CTP-L1-AP-U-HA-AE-SA-EX-156240; 156240

Transponder-coded safety switch CTP-AP, M12, ATEX ATEX version Suitable for use in zones 2 and 22 (gases and dusts) Safety switch with guard locking and integrated
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Transponder-coded safety switch CTP-L1-AP-U-HA-AE-SH-123375; 123375

Transponder-coded safety switch CTP-AP, M23, with escape release Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Transponder-coded safety switch CTP-L1-AP-U-HA-ZZ-SII-136625; 136625

Transponder-coded safety switch CTP-AP, 2 x M12 Safety switch with guard locking and integrated evaluation electronics Direct connection to decentralized peripheral
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Transponder-coded safety switch CTP-L2-AP-M-HA-AZ-SA-124729; 124729

Transponder-coded safety switch CTP-AP, M12 Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring 2 safety outputs (semiconductor
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Transponder-coded safety switch CTP-L2-AP-M-HA-AZ-SH-123371; 123371

Transponder-coded safety switch CTP-AP, M23 Safety switch with guard locking and integrated evaluation electronics Short circuit monitoring 2 safety outputs (semiconductor
-
Need to order

(Trenutno nema na stanju)

Cena na upit

1
2
3
Uporedi proizvode Ukloni sve proizvode