EUCHNER Transponder-coded safety switch CTS-C1-BP-CC-FLX-AP-VSA-171593; 171593

EUCHNER Transponder-coded safety switch CTS-C1-BP-CC-FLX-AP-VSA-171593; 171593

Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12 Up to category 4 / PL e according to EN ISO 13849-1 Closed-circuit current principle Connecting...

Brand: EUCHNER
Šifra: 171593
Dostupnost: Proveriti dostupnost
Cena na upit

Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12

  • Up to category 4 / PL e according to EN ISO 13849-1
  • Closed-circuit current principle
  • Connecting cable , PVC, 25 cm, plug connector M12, 8-pin
  • Monitoring outputs OL and OT

Approvals

FCC_CTS_2AJ58-18c_UL_us_E93776_5/1

Electrical connection values

Fuse  
IMP 1 ... 8 A external
UB 1 ... 8 A external
Power consumption 9 W
rated conditional short-circuit current 100 A
Rated insulation voltage Ui 32 V
Rated impulse withstand voltage Uimp 0.8 kV
Operating voltage DC  
   
UB 24 V DC -15% ... +20% 
Discrepancy time max. 10 ms
Turn-on time max. 400 ms
EMC protection requirements Acc. to EN 60947-5-3
Solenoid operating voltage DC 24 V DC -15% ... +20% reverse polarity protected, regulated, residual ripple<5%, SELV
Solenoid duty cycle 100 %
Risk time according to EN 60947-5-3 max. 200 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 10 ms
Switching load  
according to UL DC 24 V, class 2
Safety class  
EN IEC 61140 III
Current consumption  
IIMP 500 mA
IUB 50 mA
Degree of contamination (external, according to EN 60947-1) 3
  Monitoring outputs Ox/C
Output type p-switching, short circuit-proof
Output voltage 0.8xUB ... UB V DC
Output current  
L configuration (guard lock monitoring active) 1 ... 20 mA
I-configuration (guard lock monitoring inactive) 1 ... 10 mA
  Safety outputs FO1A/FO1B
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage  
UFO1A /UFO1B HIGH UB-4V ... UB V DC 
UFO1A /UFO1B LOW 0 ... 1 V DC
Output current  
L configuration (guard lock monitoring active) 1 ... 80 mA
I-configuration (guard lock monitoring inactive) 1 ... 75 mA
Output current  
per safety output FO1A / FO1B  
Utilization category  
DC-13 L configuration (guard lock monitoring active) 24 V 80 mA 
DC-13 I configuration (guard lock monitoring inactive) 24 V 75 mA 
Test pulse duration max. 0.3 ms
Test pulse interval min. 96 ms

Mechanical values and environment

Approach speed max. 20 m/min
Extraction force 25 N
Ready delay max. 1 s
Actuating force 25 N
Installation orientation any
Mechanical life 1 x 10⁶
Retention force 10 N
Shock and vibration resistance Acc. to EN 60947-5-3
Degree of protection IP65/IP67/IP69/IP69K
Ambient temperature -20 ... +55 °C 
Material  
Connecting cable PVC
Switch head cover Die-cast zinc
Safety switch housing Reinforced thermoplastic
Locking force Fmax 3900 N
Locking force FZh 3000 N
Guard locking principle Closed-circuit current principle
  Connection X1
Connection type Connecting cable with plug connector M12
Static bending radius 8x cable diameter
Cable outlet straight
Cable length 0.25 m
Number of pins 8
  Safety outputs FO1A/FO1B
Switching frequency max. 0.2 Hz

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

  PL Maximum SIL PFHD Category Mission time
Monitoring of the guard position PL e 3 6.44x10-9 4 20 y
Monitoring of guard locking PL e 3 6.44x10-9 4 20 y
Only applies with active guard lock monitoring (guard locking for personal protection). Depending on the actuator used.


  PL Maximum SIL Category Mission time
Control of guard locking Depending on external control of guard locking 20 y

Slicni proizvodi:


EUCHNER Transponder-coded safety switch CTS-C1-BP-CC-FLX-AP-VSA-167917; 167917

Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12 Up to category 4 / PL e according to EN ISO 13849-1 Closed-circuit current principle Connecting
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Transponder-coded safety switch CTS-C1-BP-CC-FLX-AP-VSA-169052; 169052

Transponder-coded safety switch CTS-C1-BP with FlexFunction, M12 Up to category 4 / PL e according to EN ISO 13849-1 Closed-circuit current principle Connecting
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Transponder-coded safety switch CTS-C2-BP-CC-FLX-AP-VSA-169051; 169051

Transponder-coded safety switch CTS-C2-BP with FlexFunction, M12 Up to category 4 / PL e according to EN ISO 13849-1 Guard locking suitable for process protection
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Transponder-coded safety switch CTA-L1-BP-U-HA-AP-SII-170930; 170930

Transponder-coded safety switch CTA-BP, 2 x M12 Safety switch with guard locking and integrated evaluation electronics Direct connection to decentralized peripheral
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Non-contact safety switch CET3-AR-CRA-CH-50X-SH-110104; 110104

Non-contact safety switch CET-AR-..., RC18 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Up to 20 switches in
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 ; 124987

Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle) Safety switch with guard locking and integrated evaluation
-
Need to order

(Trenutno nema na stanju)

Cena na upit

1
2
3
Uporedi proizvode Ukloni sve proizvode