EUCHNER Transponder-coded safety switch CTS-C1-BR-CC-FLX-AP-V05-169053; 169053
Transponder-coded safety switch CTS-C1-BR with FlexFunction, connecting cable with flying lead Up to category 4 / PL e according to EN ISO 13849-1 Up to 20 switches...
Cena na upit
Transponder-coded safety switch CTS-C1-BR with FlexFunction, connecting cable with flying lead
- Up to category 4 / PL e according to EN ISO 13849-1
- Up to 20 switches in series
- Closed-circuit current principle
- Connecting cable, PVC, 5 m, flying lead
- Monitoring outputs OL and OD
Approvals
Electrical connection values
Fuse | |
IMP | 1 ... 8 A external |
UB | 1 ... 8 A external |
Power consumption | 9 W |
rated conditional short-circuit current | 100 A |
Rated insulation voltage Ui | 32 V |
Rated impulse withstand voltage Uimp | 0.8 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +20% |
Discrepancy time | max. 10 ms |
Turn-on time | max. 400 ms |
EMC protection requirements | Acc. to EN 60947-5-3 |
Solenoid operating voltage DC | 24 V DC -15% ... +20% reverse polarity protected, regulated, residual ripple<5%, SELV |
Solenoid duty cycle | 100 % |
Risk time according to EN 60947-5-3 | max. 200 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
Switching load | |
according to UL | DC 24 V, class 2 |
Safety class | |
EN IEC 61140 | III |
Current consumption | |
IIMP | 500 mA |
IUB | 50 mA |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring outputs Ox/C | |
Output type | p-switching, short circuit-proof |
Output voltage | 0.8xUB ... UB V DC |
Output current | |
I-configuration (guard lock monitoring inactive) | 1 ... 10 mA |
L configuration (guard lock monitoring active) | 1 ... 20 mA |
Safety outputs FO1A/FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-4V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
L configuration (guard lock monitoring active) | 1 ... 80 mA |
I-configuration (guard lock monitoring inactive) | 1 ... 75 mA |
Output current | |
per safety output FO1A / FO1B | |
Utilization category | |
DC-13 I configuration (guard lock monitoring inactive) | 24 V 75 mA |
DC-13 L configuration (guard lock monitoring active) | 24 V 80 mA |
Test pulse duration | max. 0.3 ms |
Test pulse interval | min. 96 ms |
Mechanical values and environment
Approach speed | max. 20 m/min |
Extraction force | 25 N |
Ready delay | max. 5 s |
Actuating force | 25 N |
Installation orientation | any |
Mechanical life | 1 x 10⁶ |
Retention force | 10 N |
Shock and vibration resistance | Acc. to EN 60947-5-3 |
Degree of protection | IP65/IP67/IP69/IP69K |
Ambient temperature | -20 ... +55 °C |
Material | |
Connecting cable | PVC |
Safety switch housing | Reinforced thermoplastic |
Switch head cover | Die-cast zinc |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Guard locking principle | Closed-circuit current principle |
Connection X1 | |
Connection type | Connecting cable with flying lead |
Static bending radius | 8x cable diameter |
Cable outlet | straight |
Cable length | 5 m |
Number of pins | 8 |
Connection X2 | |
Connection type | Connecting cable with flying lead |
Static bending radius | 8x cable diameter |
Cable outlet | straight |
Cable length | 5 m |
Number of pins | 5 |
Safety outputs FO1A/FO1B | |
Switching frequency | max. 0.2 Hz |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | 3 | 6.44x10-9 | 4 | 20 y |
Monitoring of guard locking | PL e | 3 | 6.44x10-9 | 4 | 20 y |
Slicni proizvodi:
EUCHNER Transponder-coded safety switch CTS-C2-BR-CC-FLX-AP-VAB-169613; 169613
Transponder-coded safety switch CTS-C2-BR with FlexFunction, 2 x M12 Up to category 4 / PL e according to EN ISO 13849-1 Guard locking suitable for process protection
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Transponder-coded safety switch CTS-C1-BR-CC-FLX-AP-VAB-169612; 169612
Transponder-coded safety switch CTS-C1-BR with FlexFunction, 2 x M12 Up to category 4 / PL e according to EN ISO 13849-1 Up to 20 switches in series Closed-circuit
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Transponder-coded safety switch CTM-C2-BP-HC-FLX-AZ-SA-170491; 170491
Transponder-coded safety switch CTM-C2-BP, M12 Safety switch with guard locking and integrated evaluation electronics Communication functions in combination with
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Non-contact safety switch CET4-AP-CRA-CH-50X-SA-122413; 122413
Non-contact safety switch CET-AP-..., M12 Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N Short circuit monitoring
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 ; 124987
Safety switch CTP-L1-AS – with AS-i connection, plug connector M12 (closed-circuit current principle) Safety switch with guard locking and integrated evaluation
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Non-contact safety switch CET-AR-..., RC18, with escape release ; 110943
Non-contact safety switch CET-AR-..., RC18, with escape release Safety switch with guard locking and integrated evaluation electronics Locking force up to 6500 N
-
(Trenutno nema na stanju)
Cena na upit