INVERTEK DRIVES Modbus TCP Plug In Interface Module

This option module is specifically designed to be used with the Optidrive P2 and Optidrive ECO range of variable speed drive products and is intended for professional...

Brand: INVERTEK DRIVES
Šifra: OPT-2-MODIP-IN
Dostupnost: Proveriti dostupnost
Cena bez pdv-a: 27.898,17
Cena sa pdv-om: 33.477,81
   
This option module is specifically designed to be used with the Optidrive P2
and Optidrive ECO range of variable speed drive products and is intended for
professional incorporation into complete equipment or systems. If installed
incorrectly it may present a safety hazard. Before commencing installation
and commissioning, the user should ensure they are fully familiar with the
Optidrive P2, and in particular have read the important safety information and
warnings contained in the Optidrive P2 / Optidrive HVAC User Guide.

The Modbus TCP Interface is intended to be installed in the Optidrive option slot, and allows the Optidrive to be connected to a Modbus TCP network. The interface offers the following functionality :-
  • Two Ethernet IP Ports
  • 10 / 100Mbit Full / Half Duplex operation
  • Galvanically isolated
High speed cyclic data exchange

Modbus TCP Interface Card Plug In Option Module for Invertek P2, HVAC and Eco drives.

Compatible with part number prefixes:
Optidrive P2 (ODP-2-.... Drives)
Optidrive HVAC (ODV-2-... Drives)
Optidrive Eco (ODV-3-... Drives)

Requires a Torx screwdriver size T9 (T09) to fit (not included).

Two Ethernet IP Ports
10 / 100Mbit Full / Half Duplex operation
Galvanically isolated
High speed cyclic data exchange

Manufacturers part number is OPT-2-MODIP-IN

Made in the UK.

  • 82-MODTCP CC ModbusTCP User Guide IPAddressConfig Utility

    82-MODTCP CC ModbusTCP User Guide IPAddressConfig Utility



Slicni proizvodi:


INVERTEK DRIVES RJ45 BacNet connector for Optidrive Inverters - OPT-2-BNTSP-IN

The Invertek OPT-2-BNTSP-IN is a BACnet data cable splitter, designed to enable terminal block type connectivity for BACnet communication networks. Both the Optidrive
-
Need to order

(Trenutno nema na stanju)

 
 
5.290,43

INVERTEK DRIVES Modbus TCP Interface, for P2, E3, Eco; OPT-3-MTPEG-IN

Modbus TCP Interface, for P2, E3, Eco; OPT-3-MTPEG-IN
-
In stock

(Na stanju)

 
 
12.226,76

INVERTEK DRIVES Ethernet IP Interface, for P2, E3, Eco; OPT-2-ETHEG-IN

Ethernet IP Interface, for P2, E3, Eco; OPT-2-ETHEG-IN
-
Need to order

(Trenutno nema na stanju)

 
 
12.226,76

INVERTEK DRIVES Profinet Plug in Interface Module OPT-2-PFNET-IN

The PROFINET module is intended to be installed in the Optidrive option slot, and allows the Optidrive P2/HVAC/ECO to be connected to a PROFINET network.
-
In stock

(Na stanju)

 
 
23.701,10

INVERTEK DRIVES EthernetIP Plug in Interface Module OPT-2-ETHNT-IN

The Ethernet IP module is intended to be installed in the Optidrive option slot and allows the Optidrive P2/HVAC/ECO to be connected to a EthernetIP network.
-
Need to order

(Trenutno nema na stanju)

 
 
23.701,10

INVERTEK DRIVES Profibus DPV-1 Plug in Interface Module OPT-2-PROFB-IN

The PROFIBUS DP module is intended to be installed in the Optidrive option slot, and allows the Optidrive P2/HVAC/ECO to be connected to a PROFIBUS DP network.
-
In stock

(Na stanju)

 
 
30.860,81

1
2
3
Uporedi proizvode Ukloni sve proizvode