MGB-AP for use as a single device; MGB-AR for series connection up to 10 MGB-AR devices; MGB-PN for Profinet connection; MGB Ethernet/IP for Ethernet connection.

EUCHNER Locking set MGB-L1HC-ARA-R-109806; 109806

Locking set MGB-L1H-ARA... (guard locking by spring force) with 3 pushbuttons, 2 indicators, emergency stop, incl. label carrier, RC26 Guard locking with guard lock
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1H-APA-R-121369; 121369

Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1H-ARA-R-121256; 121256

Locking set MGB-L1H-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier Guard locking with guard lock monitoring Can
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L1-ARA-AM8A1-M-R-121226; 121226

Locking module MGB-L1-ARA... (guard locking by spring force) with 1 pushbutton, key-operated rotary switch, emergency stop Guard locking with guard lock monitoring
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L2H-ARA-R-117315; 117315

Locking set MGB-L2H-ARA-R... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18; 117315 Guard locking with guard lock
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L2HE-ARA-R-105788; 105788

Locking set MGB-L2HE-ARA... (guard locking by solenoid force) without control or indicator Guard locking with guard lock monitoring Can be connected in series with
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L1-ARA-AM3A1-M-L-121261; 121261

Locking module MGB-L1-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier Guard locking with guard lock monitoring Can
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L2H-ARA-R-121258; 121258

Locking set MGB-L2H-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier Guard locking with guard lock monitoring Can
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Interlocking set MGB-L0H-ARA-L-110952; 110952

Interlocking set MGB-L0H-ARA..., without controls or indicators, RC18 Interlocking (without guard locking) Can be connected in series with other AR devices (e.g.
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1HE-ARC-L-121042; 121042

Locking set MGB-L1HE-ARC... (guard locking by spring force) with 1 pushbutton, RC18, multicode Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Interlocking module MGB-L0-ARA-AA2A1-S1-R-116300; 116300

Interlocking module MGB-L0-ARA..., with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Interlocking (without guard locking) Can be connected in series
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1HE-ARA-R-121131; 121131

Locking set MGB-L1HE-ARA..., (guard locking by spring force) with 1 pushbuttons, emergency stop Guard locking with guard lock monitoring Can be connected in series
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L1-APA-AP4A1-S1-R-158117; 158117

Locking module MGB-L1-APA.. (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking set MGB-L1H-ARA-L-121414; 121414

Locking set MGB-L1H-ARA... (guard locking by spring force) with 2 pushbuttons, machine stop, incl. label carrier Guard locking with guard lock monitoring Can be
-
Need to order

(Trenutno nema na stanju)

Cena na upit

EUCHNER Locking module MGB-L1-APA-AH3A1-S1-R-115894; 115894

Locking module MGB-L1-APA... (guard locking by spring force) with 1 pushbutton, 1 indicator, emergency stop, RC18 Guard locking with guard lock monitoring Emergency
-
Need to order

(Trenutno nema na stanju)

Cena na upit


Stranica 20 od 25
Prikazano 286 - 300 od 361 podataka

Multifunctional Gate Box MGB


The MGB is a safety system with guard locking and guard lock monitoring for the protection of safety doors on machines and installations.

Economical, standard-compliant wiring

The family MGB-AP is particularly suitable for the protection of individual safety doors. If series connection is not necessary, wiring can then be saved. This version has different timing to the AR version.
All devices in the family MGB-AR can be wired directly in series in a so-called AR series connection without reducing safety or the PL. As a consequence evaluation units are saved.
AR devices are also available in the EUCHNER series CES and CET.

Seamless integration by means of bus connection

In the PROFINET version, MGB-PN, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary PROFINET input and output bytes required. Comprehensive diagnostic information in the form of PROFINET messages makes troubleshooting quick and specific. Due to the typical ease with which parameters can be set in PROFINET, even the replacement of the system in case of servicing is a simple matter and can be undertaken in a few minutes.

In the MGB Ethernet/IP™ version, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary CIP Safety input and output bytes required. Whether interlocking, guard locking, escape release or other functions such as buttons for start/stop, emergency stop, selector switch, etc. – the MGB meets all requirements for safety-related applications and can be equipped on a customer-specific basis. Comprehensive diagnostic information in the form of Ethernet/IP™ messages provides a fast and detailed overview of the device status. Due to the ease with which parameters can be set, even replacing the system during servicing is a simple matter and takes no more than a few minutes.


1
2
3
Uporedi proizvode Ukloni sve proizvode