Multifunctional Gate Box MGB
Filteri
Multifunctional Gate Box MGB
MGB-AP for use as a single device; MGB-AR for series connection up to 10 MGB-AR devices; MGB-PN for Profinet connection; MGB Ethernet/IP for Ethernet connection.
EUCHNER Locking set MGB-L1H-APA-R-115178; 115178
Locking set MGB-L1H-APA... (guard locking by spring force) with 2 pushbuttons, emergency stop Guard locking with guard lock monitoring Emergency stop according to
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L2H-ARA-R-121011; 121011
Locking set MGB-L2H-ARA... (guard locking by solenoid force) with 1 pushbutton, incl. label carrier, guard lock monitoring switched off Guard locking with guard
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L1H-ARA-L-121262; 121262
Locking set MGB-L1H-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier Guard locking with guard lock monitoring Can
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Interlocking module MGB-L0-ARA-AA1A1-S1-L-110953; 110953
Interlocking module MGB-L0-ARA..., without controls or indicators, RC18 Interlocking (without guard locking) Can be connected in series with other AR devices (e.g.
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L1H-ARA-R-111070; 111070
Locking set MGB-L1H-ARA... (guard locking by spring force) without control or indicator, RC18 Guard locking with guard lock monitoring Can be connected in series
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L1HE-APA-R-112601; 112601
Locking set MGB-L1HE-APA... (guard locking by spring force) without controls or indicators, RC18, on mounting plates Guard locking with guard lock monitoring With
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L1H-APA-L-117069; 117069
Locking set MGB-L1H-APA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. adhesive labels, RC18 Guard locking with guard lock monitoring
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L1H-ARA-L-117316; 117316
Locking set MGB-L1H-ARA... (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L2H-ARA-R-105786; 105786
Locking set MGB-L2H-ARA... (guard locking by solenoid force) without control or indicator Guard locking with guard lock monitoring Can be connected in series with
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L1H-APA-R-116428; 116428
Locking set MGB-L1H-APA... (guard locking by spring force) with 3 pushbuttons, incl. label carrier, M12 for enabling switch, RC18 Guard locking with guard lock monitoring
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking module MGB-L1-APA-AP5A1-S1-L-121378; 121378
Locking module MGB-L1-APA... (guard locking by spring force) with 3 pushbuttons, emergency stop, RC18 Guard locking with guard lock monitoring Emergency stop according
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L2H-ARA-L-121009; 121009
Locking set MGB-L2H-ARA... (guard locking by solenoid force) with 1 pushbutton, incl. label carrier, guard lock monitoring switched off Guard locking with guard
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L1HE-ARA-R-119758; 119758
Locking set MGB-L1HE-ARA..., (guard locking by spring force) with 3 pushbutton, RC18 Guard locking with guard lock monitoring Can be connected in series with other
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L1HE-ARA-L-160590; 160590
Locking set MGB-L1HE-ARA... (guard locking by spring force) with 1 pushbutton, emergency stop, selector switch Guard locking with guard lock monitoring Can be connected
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Locking set MGB-L1HE-ARA-L-121040; 121040
Locking set MGB-L1HE-ARA..., (guard locking by spring force) with 1 pushbutton, RC18 Guard locking with guard lock monitoring Can be connected in series with other
-
(Trenutno nema na stanju)
Cena na upit
Multifunctional Gate Box MGB
The MGB is a safety system with guard locking and guard lock monitoring for the protection of safety doors on machines and installations.
Economical, standard-compliant wiring
The family MGB-AP is particularly suitable for the protection of individual safety doors. If series connection is not necessary, wiring can then be saved. This version has different timing to the AR version.All devices in the family MGB-AR can be wired directly in series in a so-called AR series connection without reducing safety or the PL. As a consequence evaluation units are saved.
AR devices are also available in the EUCHNER series CES and CET.
Seamless integration by means of bus connection
In the PROFINET version, MGB-PN, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary PROFINET input and output bytes required. Comprehensive diagnostic information in the form of PROFINET messages makes troubleshooting quick and specific. Due to the typical ease with which parameters can be set in PROFINET, even the replacement of the system in case of servicing is a simple matter and can be undertaken in a few minutes.In the MGB Ethernet/IP™ version, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary CIP Safety input and output bytes required. Whether interlocking, guard locking, escape release or other functions such as buttons for start/stop, emergency stop, selector switch, etc. – the MGB meets all requirements for safety-related applications and can be equipped on a customer-specific basis. Comprehensive diagnostic information in the form of Ethernet/IP™ messages provides a fast and detailed overview of the device status. Due to the ease with which parameters can be set, even replacing the system during servicing is a simple matter and takes no more than a few minutes.