NOVUS N1200-HBD RS485 USB Process Control. heater break detec. 48x48mm ;8120200520
N1200-HBD RS485 USB Process Control. heater break detec. 48x48mm ;8120200520...
Cena bez pdv-a: 26.217,00 |
Cena sa pdv-om: 31.460,39 |
N1200-HBD RS485 USB Process Control. heater break detec. 48x48mm ;8120200520
- Input Type: TC J, K, T, N, R, S, B, E, Pt100 0-20 mA, 4-20 mA, 0-50 mV, 0-5 Vdc, 0-10 Vdc
- Accuracy: Thermocouples J, K, T: 0.25 % of span ±1 °C; Thermocouples N, R, S, B: 0.25 % of span ± 3 °C; Pt100, 0-20 mA, 4-20 mA, 0-5 Vdc, 0-10 Vdc: 0.2 % of span
- Input Resolution: 32767 levels (15 bits)
- Sampling Rate: 55 samples per second
- Analog Output: 0-20 mA or 4-20 mA
- Output Resolution: 31000 levels
- Control Type: PID, PI, PD, P; On/Off
- Control Action: Heat or Cool
- Control Output: Type SSR Pulse; 4-20 mA control; Relay
- Open Sensor Detection: Loop Break / Heater breaker detection
- Alarm Types: Minimum, Maximum, Differential, Differential, Low, Differential High, Open Sensor, Ramp and Soak Event
- Optional: Relay, Two Digital Inputs or Outputs, RS-485, Heater break detection
- Communication: RS485 Modbus optional
- Ramp and Soak programs: 20 programs with 9 segments each
Safety: Password protected configuration
- Configuration Interface: USB type Mini B (powered)
- Power Supply: 100-240 Vac/dc; 12-24 Vdc
- Maximum Consumption: 9 VA
- Front Pannel: IP65 ; Polycarbonate (PC) UL94 V-2
- 48 x 48 x 110 mm (DIN 1/16); ABS+PC UL94 V-0
- Enclosure: IP20
- Operating Conditions: 5 to 50 °C (41 to 122 °F) and 0 to 80 % RH
- Approvals: CE, RoHS, Reach, UL, and cUL
- Accuracy: Thermocouples J, K, T: 0.25 % of span ±1 °C; Thermocouples N, R, S, B: 0.25 % of span ± 3 °C; Pt100, 0-20 mA, 4-20 mA, 0-5 Vdc, 0-10 Vdc: 0.2 % of span
- Input Resolution: 32767 levels (15 bits)
- Sampling Rate: 55 samples per second
- Analog Output: 0-20 mA or 4-20 mA
- Output Resolution: 31000 levels
- Control Type: PID, PI, PD, P; On/Off
- Control Action: Heat or Cool
- Control Output: Type SSR Pulse; 4-20 mA control; Relay
- Open Sensor Detection: Loop Break / Heater breaker detection
- Alarm Types: Minimum, Maximum, Differential, Differential, Low, Differential High, Open Sensor, Ramp and Soak Event
- Optional: Relay, Two Digital Inputs or Outputs, RS-485, Heater break detection
- Communication: RS485 Modbus optional
- Ramp and Soak programs: 20 programs with 9 segments each
Safety: Password protected configuration
- Configuration Interface: USB type Mini B (powered)
- Power Supply: 100-240 Vac/dc; 12-24 Vdc
- Maximum Consumption: 9 VA
- Front Pannel: IP65 ; Polycarbonate (PC) UL94 V-2
- 48 x 48 x 110 mm (DIN 1/16); ABS+PC UL94 V-0
- Enclosure: IP20
- Operating Conditions: 5 to 50 °C (41 to 122 °F) and 0 to 80 % RH
- Approvals: CE, RoHS, Reach, UL, and cUL
Slicni proizvodi:
NOVUS N1200-HC USB 24V Heating/Cool. controller 2 relays, 48x48 mm; 81202HC124
N1200-HC USB 24V Heating/Cool. controller 2 relays, 48x48 mm; 81202HC124
-
(Trenutno nema na stanju)
Cena na upit
NOVUS N1200 USB Process controller, 2 relays, 48x48 mm; 8120200120
N1200 USB Process controller, 2 relays, 48x48 mm; 8120200120
-
(Trenutno nema na stanju)
18.457,71
NOVUS N1200 USB 24V Process controller, 2 relays, 48x48 mm; 8120200124
N1200 USB 24V Process controller, 2 relays, 48x48 mm; 8120200124
-
(Trenutno nema na stanju)
18.810,40
NOVUS N1200-HBD RS485 USB 24V Process Controller heater break detec. 48x48mm; 8120200524
N1200-HBD RS485 USB 24V Process Controller heater break detec. 48x48mm; 8120200524
-
(Trenutno nema na stanju)
26.452,13