Siemens ET 200SP HA, EX-AI 2xI 2-WIRE HART; 6DL1134-6TB00-0HX1
SIMATIC ET 200SP HA, ET 200SP, analog ex-i HART input module, Ex-AI 2xI 2-Wire HART, suitable for BaseUnit type X1, channel diagnostics, 16bit, +/-0.3%...
Cena na upit
SIMATIC ET 200SP HA, ET 200SP, analog ex-i HART input module, Ex-AI 2xI 2-Wire HART, suitable for BaseUnit type X1, channel diagnostics, 16bit, +/-0.3% |
General information | |
Product type designation | Ex-AI 2xI 2-wire HART |
Firmware version | V1.0 |
● FW update possible | Yes |
usable BaseUnits | BU type X1 |
Product function | |
● I&M data | Yes; I&M0 to I&M3 |
● Isochronous mode | No |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from version | STEP 7 V16 or higher with HSP |
● STEP 7 configurable/integrated from version | STEP 7 V5.6 SP2 or higher |
● PCS 7 configurable/integrated from version | V9.1 |
Operating mode | |
● MSI | Yes |
Redundancy | |
● Redundancy capability | No |
CiR - Configuration in RUN | |
Reparameterization possible in RUN | Yes |
Input current | |
Current consumption (rated value) | 74 mA |
Current consumption, max. | 92 mA; Peak load (all channels in short-circuit) |
Encoder supply | |
24 V encoder supply | |
● 24 V | Yes |
● Short-circuit protection | Yes; Electronic disconnection in case of short-circuit, current limitation from 27 mA |
● Output current per channel, max. | 28 mA |
Power loss | |
Power loss, typ. | 1.2 W |
Address area | |
Address space per module | |
● Address space per module, max. | 4 byte; + 0/1 byte for QI information |
● Address space per module with HART, max. | 24 byte; + 0/1 byte for QI information |
● Address space per module with MultiHART, max. | 11 byte; + 0/1 byte for QI information |
Hardware configuration | |
Automatic encoding | |
● Mechanical coding element | Yes |
Selection of BaseUnit for connection variants | |
● 2-wire connection | BU type X1 |
Analog inputs | |
Number of analog inputs | 2; Differential inputs |
● For current measurement | 2 |
Cycle time (all channels), min. | 3 ms |
Input ranges (rated values), currents | |
● 0 to 20 mA | Yes |
● 4 mA to 20 mA | Yes; 15 bit + sign |
— Input resistance (4 mA to 20 mA) | 400 Ω; At 20 mA input current |
Cable length | |
● shielded, max. | 500 m; Ex characteristic values must be observed |
● unshielded, max. | 300 m; Ex characteristic values must be observed |
Analog value generation for the inputs | |
Measurement principle | integrating (Sigma-Delta) |
Integration and conversion time/resolution per channel | |
● Resolution with overrange (bit including sign), max. | 16 bit |
● Integration time, parameterizable | Yes; channel by channel |
● Interference voltage suppression for interference frequency f1 in Hz | 10 / 50 / 60 Hz |
Smoothing of measured values | |
● Number of smoothing levels | 4; None; 4/8/16 times |
● parameterizable | Yes |
Encoder | |
Connection of signal encoders | |
● for current measurement as 2-wire transducer | Yes |
— Burden of 2-wire transmitter, max. | 750 Ω; At 20 mA input current |
Errors/accuracies | |
Linearity error (relative to input range), (+/-) | 0.01 % |
Temperature error (relative to input range), (+/-) | 0.005 %/K |
Crosstalk between the inputs, min. | 60 dB |
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.05 % |
Operational error limit in overall temperature range | |
● Current, relative to input range, (+/-) | 0.3 % |
Basic error limit (operational limit at 25 °C) | |
● Current, relative to input range, (+/-) | 0.2 % |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | |
● Series mode interference (peak value of interference < rated value of input range), min. | 60 dB |
Protocols | |
HART protocol | Yes |
Slicni proizvodi:
Siemens ET 200SP AI Energy Meter CT HF; 6ES7134-6PA01-0CU0
SIMATIC ET 200SP, analog input module, AI Energy Meter CT HF, for 1A or 5A current transformer, with network analysis functions, suitable for BU type U0, channel
-
(Trenutno nema na stanju)
Cena na upit
Siemens ET 200SP AI Energy Meter RC HF; 6ES7134-6PA21-0CU0
SIMATIC ET 200SP, analog input module, AI Energy Meter RC HF, for Rogowski coils or current/voltage transformer 333 mV, with network analysis functions, suitable
-
(Trenutno nema na stanju)
Cena na upit
Siemens ET 200SP, AI 8xRTD/TC 2-Wire HF; 6ES7134-6JF00-0CA1
SIMATIC ET 200SP, Analog input module, AI 8xRTD/TC 2-wire High Feature suitable for BU type A0, A1, Color code CC00, channel diagnostics, 16 bit, +/-0.1%
-
(Trenutno nema na stanju)
Cena na upit
Siemens ET 200SP AI 2 X U/I 2-, 4-Wire HF; 6ES7134-6HB00-0CA1
SIMATIC ET 200SP, Analog input module, AI 2x U/I 2-.4-wire High Feat., suitable for BU type A0, A1, Color code CC05, channel diagnostics, 16 bit, +/-0.1%
-
(Trenutno nema na stanju)
Cena na upit
Siemens ET 200SP AI Energy Meter CT ST; 6ES7134-6PA01-0BU0