Siemens SIMATIC HMI KTP900 Basic; 6AV2123-2JB03-0AX0
SIMATIC HMI, KTP900 Basic, Basic Panel, Key/touch operation, 9" TFT display, 65536 colors, PROFINET interface, configurable from WinCC Basic V13/ STEP 7 Basic...
Cena bez pdv-a: 152.839,20 |
Cena sa pdv-om: 183.407,04 |
SIMATIC HMI, KTP900 Basic, Basic Panel, Key/touch operation, 9" TFT display, 65536 colors, PROFINET interface, configurable from WinCC Basic V13/ STEP 7 Basic V13, contains open-source software, which is provided free of charge see enclosed CD
General information |
||
Product type designation | KTP900 Basic color PN | |
Display | ||
Design of display | TFT widescreen display, LED backlighting | |
Screen diagonal | 9 in | |
Display width | 198 mm | |
Display height | 111.7 mm | |
Number of colors | 65 536 | |
Resolution (pixels) | ||
● Horizontal image resolution | 800 pixel | |
● Vertical image resolution | 480 pixel | |
Backlighting | ||
● MTBF backlighting (at 25 °C) | 20 000 h | |
● Backlight dimmable | Yes | |
Control elements | ||
Keyboard fonts | ||
● Function keys | ||
— Number of function keys | 8 | |
— Number of function keys with LEDs | 0 | |
● Keys with LED | No | |
● System keys | No | |
● Numeric keyboard | Yes; Onscreen keyboard | |
● alphanumeric keyboard | Yes; Onscreen keyboard | |
Touch operation | ||
● Design as touch screen | Yes; Analog-resistive | |
Installation type/mounting | ||
Mounting position | vertical | |
Mounting in portrait format possible | Yes | |
Mounting in landscape format possible | Yes | |
maximum permissible angle of inclination without external ventilation | 35° | |
Supply voltage | ||
Type of supply voltage | DC | |
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
Input current | ||
Current consumption (rated value) | 230 mA | |
Starting current inrush I²t | 0.2 A²·s | |
Power | ||
Active power input, typ. | 5.5 W | |
Processor | ||
Processor type | ARM | |
Memory | ||
Flash | Yes | |
RAM | Yes | |
Memory available for user data | 10 Mbyte | |
Type of output | ||
Acoustics | ||
● Buzzer | Yes | |
● Speaker | No | |
Time of day | ||
Clock | ||
● Hardware clock (real-time) | Yes | |
● Software clock | Yes | |
● retentive | Yes; Back-up duration typically 6 weeks | |
● synchronizable | Yes | |
Interfaces | ||
Number of industrial Ethernet interfaces | 1 | |
Number of RS 485 interfaces | 0 | |
Number of RS 422 interfaces | 0 | |
Number of RS 232 interfaces | 0 | |
Number of USB interfaces | 1; Up to 16 GB | |
Number of 20 mA interfaces (TTY) | 0 | |
Number of parallel interfaces | 0 | |
Number of other interfaces | 0 | |
Number of SD card slots | 0 | |
With software interfaces | No | |
Industrial Ethernet | ||
● Industrial Ethernet status LED | 2 | |
Protocols | ||
PROFINET | Yes | |
Supports protocol for PROFINET IO | No | |
IRT | No | |
PROFIBUS | No | |
EtherNet/IP | Yes | |
MPI | No | |
Protocols (Ethernet) | ||
● TCP/IP | Yes | |
● DHCP | Yes | |
● SNMP | Yes | |
● DCP | Yes | |
● LLDP | Yes | |
WEB characteristics | ||
● HTTP | No | |
● HTML | No | |
Redundancy mode | ||
Media redundancy | ||
— MRP | No | |
Further protocols | ||
● CAN | No | |
● MODBUS | Yes; Modicon (MODBUS TCP/IP) | |
Interrupts/diagnostics/status information | ||
Diagnoses | ||
● Diagnostic information readable | No | |
EMC | ||
Emission of radio interference acc. to EN 55 011 | ||
● Limit class A, for use in industrial areas | Yes | |
● Limit class B, for use in residential areas | No | |
Degree and class of protection | ||
IP (at the front) | IP65 | |
IP (rear) | IP20 | |
NEMA (front) | ||
● Enclosure Type 4 at the front | Yes | |
● Enclosure Type 4x at the front | Yes | |
Standards, approvals, certificates | ||
CE mark | Yes | |
cULus | Yes | |
RCM (formerly C-TICK) | Yes | |
KC approval | Yes | |
Use in hazardous areas | ||
● ATEX Zone 2 | No | |
● ATEX Zone 22 | No | |
● IECEx Zone 2 | No | |
● IECEx Zone 22 | No | |
● cULus Class I Zone 1 | No | |
● cULus Class I Zone 2, Division 2 | No | |
● FM Class I Division 2 | No | |
Marine approval | ||
● Germanischer Lloyd (GL) | Yes | |
● American Bureau of Shipping (ABS) | Yes | |
● Bureau Veritas (BV) | Yes | |
● Det Norske Veritas (DNV) | Yes | |
● Lloyds Register of Shipping (LRS) | Yes | |
● Nippon Kaiji Kyokai (Class NK) | Yes | |
● Polski Rejestr Statkow (PRS) | No | |
● Chinese Classification Society (CCS) | No | |
Ambient conditions | ||
Ambient temperature during operation | ||
Operation (vertical installation) | ||
— For vertical installation, min. | 0 °C | |
— For vertical installation, max. | 50 °C | |
Operation (max. tilt angle) | ||
— At maximum tilt angle, min. | 0 °C | |
— At maximum tilt angle, max. | 40 °C | |
Operation (vertical installation, portrait format) | ||
— For vertical installation, min. | 0 °C | |
— For vertical installation, max. | 40 °C | |
Operation (max. tilt angle, portrait format) | ||
— At maximum tilt angle, min. | 0 °C | |
— At maximum tilt angle, max. | 35 °C | |
Ambient temperature during storage/transportation | ||
● min. | -20 °C | |
● max. | 60 °C | |
Relative humidity | ||
● Operation, max. | 90 %; no condensation | |
Operating systems | ||
proprietary | Yes | |
pre-installed operating system | ||
● Windows CE | No | |
configuration / header | ||
Message indicator | Yes | |
Alarm system (incl. buffer and acknowledgment) | Yes | |
Process value display (output) | Yes | |
Process value default (input) possible | Yes | |
Recipe management | Yes | |
Configuration software | ||
● STEP 7 Basic (TIA Portal) | Yes; via integrated WinCC Basic (TIA Portal) | |
● STEP 7 Professional (TIA Portal) | Yes; via integrated WinCC Basic (TIA Portal) | |
● WinCC flexible Compact | No | |
● WinCC flexible Standard | No | |
● WinCC flexible Advanced | No | |
● WinCC Basic (TIA Portal) | Yes | |
● WinCC Comfort (TIA Portal) | Yes | |
● WinCC Advanced (TIA Portal) | Yes | |
● WinCC Professional (TIA Portal) | Yes | |
Languages | ||
Online languages | ||
● Number of online/runtime languages | 10 | |
Project languages | ||
● Languages per project | 32 | |
Functionality under WinCC (TIA Portal) | ||
Libraries | Yes | |
Applications/options | ||
● Web browser | Yes | |
● SIMATIC WinCC Sm@rtServer | Yes; Available with WinCC (TIA Portal) V14 or higher | |
Number of Visual Basic Scripts | No | |
Task planner | Yes | |
● time-controlled | No | |
● task-controlled | Yes | |
Help system | Yes | |
● Number of characters per info text | 500 | |
Message system | ||
● Number of alarm classes | 32 | |
● Bit messages | ||
— Number of bit messages | 1 000 | |
● Analog messages | ||
— Number of analog messages | 25 | |
● S7 alarm number procedure | No | |
● System messages HMI | Yes | |
● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... ) | Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 | |
● Number of characters per message | 80 | |
● Number of process values per message | 8 | |
● Acknowledgment groups | Yes | |
● Message indicator | Yes | |
● Message buffer | ||
— Number of entries | 256 | |
— Circulating buffer | Yes | |
— retentive | Yes | |
— maintenance-free | Yes | |
Recipe management | ||
● Number of recipes | 50 | |
● Data records per recipe | 100 | |
● Entries per data record | 100 | |
● Size of internal recipe memory | 256 kbyte | |
● Recipe memory expandable | No | |
Variables | ||
● Number of variables per device | 800 | |
● Number of variables per screen | 100 | |
● Limit values | Yes | |
● Multiplexing | Yes | |
● Structures | No | |
● Arrays | Yes | |
Images | ||
● Number of configurable images | 250 | |
● Permanent window/default | Yes | |
● Global image | Yes | |
● Pop-up images | No | |
● Slide-in images | No | |
● Image selection by PLC | Yes | |
● Image number in the PLC | Yes | |
Image objects | ||
● Number of objects per image | 100 | |
● Text fields | Yes | |
● I/O fields | Yes | |
● Graphic I/O fields (graphics list) | Yes | |
● Symbolic I/O fields (text list) | Yes | |
● Date/time fields | Yes | |
● Switches | Yes | |
● Buttons | Yes | |
● Graphic display | Yes | |
● Icons | Yes | |
● Geometric objects | Yes | |
Complex image objects | ||
● Number of complex objects per screen | 10 | |
● Alarm view | Yes | |
● Trend view | Yes | |
● User view | Yes | |
● Status/control | No | |
● Sm@rtClient view | No | |
● Recipe view | Yes | |
● f(x) trend view | No | |
● System diagnostics view | Yes; System message buffer of the SIMATIC S7-1200 and S7-1500 | |
● Media Player | No | |
● HTML browser | Yes | |
● PDF display | No | |
● IP camera display | No | |
● Bar graphs | Yes | |
● Sliders | No | |
● Pointer instruments | No | |
● Analog/digital clock | No | |
Lists | ||
● Number of text lists per project | 300 | |
● Number of entries per text list | 100 | |
● Number of graphics lists per project | 100 | |
● Number of entries per graphics list | 100 | |
Archiving | ||
● Number of archives per device | 2; One message and one process value archive | |
● Number of entries per archive | 10 000 | |
● Message archive | Yes | |
● Process value archive | Yes | |
● Archiving methods | ||
— Sequential archive | Yes | |
— Short-term archive | Yes | |
● Memory location | ||
— Memory card | No | |
— USB memory | Yes | |
— Ethernet | No | |
● Data storage format | ||
— CSV | No | |
— TXT | Yes | |
— RDB | No | |
Security | ||
● Number of user groups | 50 | |
● Number of user rights | 32 | |
● Number of users | 50 | |
● Password export/import | Yes | |
● SIMATIC Logon | No | |
Character sets | ||
● Keyboard fonts | ||
— US English | Yes | |
Transfer (upload/download) | ||
● MPI/PROFIBUS DP | No | |
● USB | No | |
● Ethernet | Yes | |
● using external storage medium | Yes | |
Process coupling | ||
● S7-1200 | Yes | |
● S7-1500 | Yes | |
● S7-200 | Yes | |
● S7-300/400 | Yes | |
● LOGO! | Yes | |
Slicni proizvodi:
Siemens SIMATIC HMI KTP400 Basic; 6AV2123-2DB03-0AX0
SIMATIC HMI, KTP400 Basic, Basic Panel, Key/touch operation, 4" TFT display, 65536 colors, PROFINET interface, configurable from WinCC Basic V13/ STEP 7 Basic
-
(Trenutno nema na stanju)
48.201,65
Siemens SIMATIC HMI KTP700 Basic; 6AV2123-2GB03-0AX0
SIMATIC HMI, KTP700 Basic, Basic Panel, Key/touch operation, 7" TFT display, 65536 colors, PROFINET interface, configurable from WinCC Basic V13/ STEP 7 Basic
-
(Trenutno nema na stanju)
87.617,67
Siemens SIMATIC HMI KTP1200 Basic; 6AV2123-2MB03-0AX0
SIMATIC HMI, KTP1200 Basic, Basic Panel, Key/touch operation, 12" TFT display, 65536 colors, PROFINET interface, configurable from WinCC Basic V13/ STEP 7 Basic
-
(Na stanju)
218.732,03
Siemens SIMATIC HMI TP400 Basic; 6AV2143-6DB00-0AA0
SIMATIC HMI, TP400 Basic Keyless; Basic Panel, neutral design, touch operation, 4" TFT display, 65536 colors, PROFINET interface, configurable from WinCC Basic
-
(Trenutno nema na stanju)
46.203,05
Siemens SIMATIC HMI KTP1200 Basic; 6AV2123-2MB03-0AX0
SIMATIC HMI, KTP1200 Basic, Basic Panel, Key/touch operation, 12" TFT display, 65536 colors, PROFINET interface, configurable from WinCC Basic V13/ STEP 7 Basic
-
(Na stanju)