Transponder-coded safety switches without guard locking
Filteri
Transponder-coded safety switches without guard locking
Transponder-coded safety switches without guard locking makes transponder technology available to protect even very small guards and doors.
EUCHNER Non-contact safety switches CES-I-AR-M-C04-USA-119479; 119479
Non-contact safety switches CES-I-AR-.-C04-…, M12 Safety switch with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Non-contact safety switch CES-AR-CR2-CH-SA-105745; 105745
Non-contact safety switch CES-AR-CR2-... , plug connector M12, PUR Safety switch with integrated evaluation electronics Up to 20 switches in series Short circuit
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Actuator CES-A-BBN-106600; 106600
EUCHNER Actuator CES-A-BBN-106600; 106600 // Cube-shaped design 42 x 25 mm Mounting compatible with actuator CES-A-BBA/BCA
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Actuator CES-A-BBN-C04; 115271
EUCHNER Actuator CES-A-BBN-C04; 115271 Cube-shaped design 42 x 25 mm Two safety screws M4x20 and rubber support included
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Non-contact safety switches CES-I-AP-U-C04-U05; 116503
Non-contact safety switches CES-I-AP-.- C04-…, flying lead Safety switch with integrated evaluation electronics No series connection Short circuit monitoring
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Non-contact safety switch CES-AP-C01-AH-SB ; 111145
Non-contact safety switch CES-AP-C01-AH-SB ; 111145 Safety switch with integrated evaluation electronics No series connection Short circuit monitoring 2 safety outputs
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Non-contact safety switch CES-AR-C01-AH-SA ; 098941
Non-contact safety switch CES-AR-C01-AH-SA ; 098941 Safety switch with integrated evaluation electronics Up to 20 switches in series Short circuit monitoring 2 safety
-
(Trenutno nema na stanju)
Cena na upit
EUCHNER Evaluation unit CES-A-AEA-02B/CES-A-UEA-02B (for 2 read heads) ; 092560
Evaluation unit CES-A-AEA-02B/CES-A-UEA-02B (for 2 read heads) ; 092560 2 read heads can be connected 2 safety contacts (relay contacts) 1 internal normally open
-
(Trenutno nema na stanju)
Cena na upit
Transponder-coded safety switches without guard locking
Safety switch CES-A-C5.../CES-A-W5...
- Safety switch with integrated evaluation electronics
- 2 safety outputs (semiconductor outputs)
- Pulsed signals can be switched
- Unicode and multicode switches
- Connection via M12 plug connector
- Standard housing according to IEC/EN 60947-5-2, IP 67
- Up to category 4 / PL e according to EN ISO 13849-1
Safety switch CES-AP
Your advantages- High level of protection against tampering
- Category 4 / PL e according to EN ISO 13849-1
- Integrated short circuit monitoring
- Large actuating range
- Connection via plug connector
- Diagnostics using LED
Safety switch CES-AR
Your advantages- Up to 20 safety switches can be connected in series
- Integrated short circuit monitoring by pulsing
- Large actuating range
- High level of protection against tampering
- Adjustable actuating head with 5 approach directions (only housing C01)
- Mounting compatible with standard housing according to EN 60947-5-2 (only housing C01)
- Diagnostics using LED
CES-C14 safety switch encapsulated in epoxy resin
Your advantages- The use of epoxy resin provides extremely high resistance to aggressive media
- Housing material suitable for the food industry
- Tested for material resistance in accordance with Ecolab specifications
- High-quality PUR cable sheath
- High degree of protection IP65/IP67/IP69
- Diagnostic LEDs are easily visible through the transparent sleeve
- Large actuating range in frontal and lateral approach directions
- Transponder with unique coding provides high level of protection against tampering
CES-BR safety switch
Your advantages- Communicating safety switch. Possible to connect up to 20 safety switches in series
- Industry 4.0 ready
- Integrated short circuit monitoring by pulsing
- Large actuating range
- High level of protection against tampering
- Diagnostics using LED
- Two safe semiconductor outputs
- Suitable for applications in category 4 / PL e according to EN ISO 13849-1
CES-BP safety switch
Your advantages- Communicating safety switch for separate operation
- Industry 4.0 ready
- Direct connection to IP67 field modules for various decentralized peripheral systems
- Two safe semiconductor outputs
- Own pulsing for short circuit monitoring
- High level of protection against tampering
- category 4 / PL e according to EN ISO 13849-1
- Connection via M12 plug connector
- Cable lengths up to 200 m permissible
- Diagnostics using LED
Safety switch CTP-I-AP
Your advantages- Safety switch without guard locking with interlocking function
- Integrated CES-AP electronics
- A special evaluation unit is not required
- Safety category 4 and PL e according to EN ISO 13849-1
- Mounting compatible with existing safety switches
- With latching function
AR evaluation unit
Your advantages- Quick overview of the status of each switch in the chain
- Safety relay already integrated
- Reduced wiring work due to AR technology
- Easy to service due to plug-in connection terminals